16 - 74
16. INDEXER POSITIONING OPERATION
(2) Parameter write inhibit
Parameter
Initial
value
Unit Setting
range
No. Symbol
Name
PA19 *BLK Parameter write inhibit
000Ch
Refer to the text.
POINT
This parameter is made valid when power is switched off, then on after
setting.
In the factory setting, this servo amplifier allows changes to the basic setting parameter, gain/filter
parameter and extension setting parameter settings. With the setting of parameter No.PA19, write can be
disabled to prevent accidental changes.
The following table indicates the parameters which are enabled for reference and write by the setting of
parameter No.PA19. Operation can be performed for the parameters marked .
Parameter No.PA19
setting
Setting operation
Basic setting
parameters
No.PA
Gain/Filter
parameters
No.PB
Extension setting
parameters
No.PC
I/O setting
parameters
No.PD
0000h
Reference
Write
000Bh
Reference
Write
000Ch
(initial value)
Reference
Write
100Bh
Reference
Write
Parameter No.
PA19 only
100Ch
Reference
Write
Parameter No.
PA19 only
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...