5 - 23
5. OPERATION
ON
OFF
ON
OFF
Servo-on (RYn0)
ON
Speed data 2
Speed data 1
Position data 2
Position data 1
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Ready (RD)
In position (RXn1)
Rough match (RXn2)
Servo motor speed
0r/min
ON
OFF
3ms or less
OFF
Forward rotation start (RYn1)
6ms or more
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
6ms or more
Movement completion (RXnC)
Automatic/manual selection
(RYn6)
Position/speed specifying
system selection (RY(n+2)A)
Incremental value/absolute
value selection (RY(n+2)B)
Position data
(RWwn+4 RWwn+5)
Speed data (RWwn+6)
Forward
rotation
Reverse
rotation
(Note 1)
(Note 1)
Incremental
value data 1
Incremental
value data 2
(Note 2)
Position command execution
demand (RY(n+2)0)
Position command execution
completion (RX(n+2)0)
(Note 2)
Speed command execution
demand (RY(n+2)1)
Speed command execution
completion (RX(n+2)1)
Trouble (ALM)
Note 1. Configure a sequence that changes the point table selection earlier, considering the delay time of CC-Link communication.
2. For details of the operation timing of RY(n 2)0 and RY(n 2)1, refer to the section 3.6.2 (3).
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...