background image

ILD1000G Installation Handbook 

Handbook Contents 

 Safety 

 Introduction 

 Quick 

Start 

 Installation 

 Overview 

 Troubleshooting 

 Accessories 

 Technical 

Specifications 

 Warranty 

 

Declaration Of Conformity 

Box Contents 

1 x ILD1000G 
1 x Loop connector 
1 x Status socket connector 
1 x ‘Installation Handbook’ 
2 x 1U Rack mounting ears 
1 x Power cable 
1 x Deaf logo 
 
 
 

 
 

 

 This symbol is used to alert the user to important 
 operating or maintenance instructions. 
 

 The Lightning bolt triangle is used to alert the user 
 to the risk of electric shock. 
 

SAFETY 

1. 

It is important to read these instructions, and to follow them. 

2. 

Keep this instruction manual in an accessible place. 

3. 

Clean only with a dry cloth. Cleaning fluids may effect the equipment. 

4. 

 

Do not block any ventilation openings. Install in accordance with the 
manufacturer’s instructions. 

5. 

Do not install this equipment near any heat sources such as radiators, heating vents 

or other apparatus that produces heat. 

6. 

 

WARNING – THIS APPARATUS MUST BE EARTHED / GROUNDED. 

7. 

Only power cords with the correct power connector may be used to maintain safety. 
Cables incorporating the UK 13A fused plug, Schuko with earthing contacts and UL 
approved “grounding type” are acceptable. These must be plugged into power outlets 
which provide a protective earth. 

8. 

Refer all servicing to qualified personnel. Servicing is required when the apparatus 
has been damaged in any way, such as a power supply cord or plug is damaged, 
liquid has been spilled or objects have fallen into the apparatus, the apparatus has 
been exposed to any rain or moisture, does not operate normally or has been 
dropped. 

9. 

 

WARNING – To reduce the risk of fire or electric shock, do not expose this 
apparatus to rain or moisture. The apparatus shall not be exposed to dripping 
or splashing and no objects filled with liquids, such as vases, shall be placed 
on the apparatus.

 

 

TO PREVENT ELECTRIC SHOCK DO NOT REMOVE THE 
COVER. THERE ARE NO USER SERVICEABLE PARTS 
INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL

.

 

Содержание ILD1000G

Страница 1: ...rs heating vents or other apparatus that produces heat 6 WARNING THIS APPARATUS MUST BE EARTHED GROUNDED 7 Only power cords with the correct power connector may be used to maintain safety Cables incorporating the UK 13A fused plug Schuko with earthing contacts and UL approved grounding type are acceptable These must be plugged into power outlets which provide a protective earth 8 Refer all servici...

Страница 2: ...s a very quick guide to setting up the amplifier All you need is an ac power source a signal source and a loop See Designing Induction Loops handbook supplied or contact Ampetronic for advice Installation 1 Turn all controls fully anti clockwise 2 Connect loop cable of appropriate length gauge 3 Connect signal input s 4 Connect power See points 6 and 7 in SAFETY section 5 If rackmounted remove all...

Страница 3: ...onnection of 3 pole Plug with balanced signals Use Twin screened cable Signal hot Signal cold INPUT 3 INPUT 1 2 SLAVE I O LOOP CONNECTOR Signal TIP SOURCE SLEEVE RING Connection of 3 pole plug Use Twin screened cable Must be 3m or less Unbalanced Balanced TIP RECORDING DEVICE SLEEVE RING Connection of 3 pole Plug to use Slave I O socket for recording output Signal 1 2 1 2 LOOP ...

Страница 4: ...in Input 2 Gain Input 3 Gain 15V 15V Current Input 3 Loop Output Loop Output Monitor Gain Boost Gain Boost Compressor Compressor Phantom Power Switch Phantom Power Switch Overload LED Overload LED Loop Error LED Loop Error LED 15V Power Supply Power LED 230V or 120V AC Power 15V 0V Power Switch 15V 150mA DC Output Socket 0V 15V 15V Use cablesupplied Must be 3m or less Use cablesupplied Must be 3m ...

Страница 5: ...nt Small hand tools including a wire stripper and a small flat blade screwdriver will be required An ILR3 loop receiver or a magnetic field strength meter is vital to check that the loop system is providing the desired level of performance A pair of stereo headphones with a 3 5mm jack plug connection is also useful to monitor the loop signal System Requirements The induction loop cable itself shou...

Страница 6: ...ctor switch in the appropriate position using a 3 pole XLR plug wired as per Connections drawing Line level signals From other audio equipment such as PA system mixing desk or CD player Connect to INPUT 2 with selector switch in the appropriate position using a 3 pole XLR plug and INPUT 3 using a 3 pole balanced jack plug both wired as per Connections drawing You may use either or all three inputs...

Страница 7: ... As a result of this analysis adjust the CURRENT and set the MLC to achieve the best sound quality This should result in adequate magnetic field strength and a level frequency response in order to satisfy IEC60118 4 Note Do NOT adjust the MLC control whilst listening to the MONITOR socket as this will not give a true indication of the response of the actual loop Once the CURRENT and MLC controls h...