5 - 52
5. OPERATION
5.6.12 Dogless Z-phase reference home position return method
The home position is determined to be where the first Z-phase pulse is issued after the home position return is
started.
(1) Devices, parameters
Set the input devices and parameters as indicated below.
Item Device/Parameter
used
Description
Manual home position return mode
selection
Automatic/manual selection (RYn6)
Turn RYn6 ON.
Point table No. selection 1 to 8
(RYnA to RYnE, RY(n 2)3 to RY(n 2)5)
RYnA to RYnE, RY(n 2)3 to
RY(n 2)5 are turned off.
Remote register-based
position/speed setting
(Only when two stations are
occupied)
Position/speed specifying system selection
(RY(n 2)A)
Turn RY(n 2)A ON.
Dog cradle type home position return Parameter No.PC02
A: Select the dog cradle type.
Home position return direction
Parameter No.PC03
Refer to section 5.6.1 (2) and select
the home position return direction.
Home position return speed
Parameter No.PC04
Set the speed till the Z-phase is
detected.
Creep speed
Parameter No.PC05
Set the speed after the Z-phase is
detected.
Home position shift distance
Parameter No.PC06
Set when the home position is moved
from the Z-phase signal position.
Home position return
acceleration/deceleration time
constants
Point table No.1
Use the acceleration/deceleration time
constant of point table No.1.
Home position return position data
Parameter No.PC07
Set the current position at home
position return completion.
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...