4 - 47
4. SIGNALS AND WIRING
2) 400V class
MCCB
MC
MCCB
U
V
W
B1
B2
U
V
W
Malfunction
(ALM)
RA1
24VDC
M
24VDC
L
1
L
2
L
3
BU
BV
BW
B
Servo amplifier
50m or less
Servo motor
Cooling fan
(Note 2)
DOCOM
DICOM
ALM
MBR
(Note 5)
RA1
RA2
(Note 6)
(Note 1)
OHS1
OHS2
(Note 3)
RA3
Servo motor
thermal
TE
CN6
Electromagnetic
brake 24VDC
power supply
Electromagnetic
brake interlock
(MBR)
(Note 7)
RA3
RA2
(Note 4)
Cooling fan power
supply
3-phase
380 to
480VAC
Note 1. There is no polarity in electromagnetic brake terminals B1 and B2.
2. BW is not available when a 1-phase power supply is used.
3. Configure the power supply circuit which turns off the magnetic contactor after detection of servo motor thermal.
4. For the cooling fan power supply, refer to (3) (b) in this section.
5. When using a servo motor with an electromagnetic brake, assign the electromagnetic brake interlock (MBR) to an
external output signal with parameters No.PD09 to PD11.
6. Do not use the 24VDC interface power supply for the electromagnetic brake.
7. Shut off the circuit by interlocking with the emergency stop switch.
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...