3 - 8
3. CC-LINK COMMUNICATION FUNCTIONS
3.4 Servo amplifier setting
(1) Servo amplifier side operation modes
This servo amplifier has the following operation modes.
Operation mode
Description
Test operation mode
Parameter unit or personal computer in which MR Configurator is installed is used to run the
servo motor.
CC-Link operation mode
CC-Link communication functions are used to operate the servo with the programmable
controller programs.
(2) Operation mode changing
(a) Operation mode changing conditions
Change the operation mode after making sure that.
1) The servo motor is at a stop.
2) The forward rotation start (RYn1) or reverse rotation start (RYn2) is OFF.
(b) Operation mode changing method
When changing from test operation to CC-Link operation, deselect test operation by switching power
OFF/ON.
Test operation mode is selected using a parameter unit
or a personal computer in which MR Configurator is
installed.
Deselect test operation mode by switching power
OFF/ON.
CC-Link
operation mode
Test operation mode
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...