5 - 20
5. OPERATION
2) Incremental value command system
The position data of the incremental value command system is the sum of the position data of the
consecutive point tables.
The operation pattern example given below assumes that the set values are as indicated in the
following table.
Point table
No.
Position data
[ 10
STM
m]
Servo motor
speed [r/min]
Acceleration time constant
[ms]
Deceleration time constant
[ms]
Dwell [ms]
(Note 1)
Auxiliary
function
1 5.00 3000
100
150
0 1
2 6.00 2000
Invalid
Invalid
0 1
3 3.00 1000
Invalid
Invalid
0
0
(Note
2)
Note 1. Always set "0".
2. Always set "0" to the auxiliary function of the last point table among the consecutive point tables.
ON
OFF
0r/min
0
5.00
11.00
14.00
1
5.00
6.00
3.00
Servo motor speed
Position address
Selected point table No.
Speed
(2000)
Speed
(3000)
Speed
(1000)
Forward
rotation
Point table No. out put
(RX(n+2)2 to RX(n+2)9)
(Note)
Forward rotation start (RYn1)
1
Acceleration time constant
of point table No.1 (100)
Deceleration time constant
of point table No.1 (150)
Note. Turning on Reverse rotation start (RYn2) starts positioning in the reverse rotation direction.
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...