5 - 47
5. OPERATION
(2) Timing chart
0
Automatic/manual selection
(RYn6)
Selected point table No.
Forward rotation start (RYn1)
Reverse rotation start (RYn2)
Servo motor speed
Forward
rotation
0r/min
Reverse
rotation
Z-phase
Proximity dog (DOG)
Rough match (RXn2)
Movement completion (RXnC)
Home position return
completion (RXn3/ZP)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
4ms or more (Note)
6ms or more
Home position return speed
Creep speed
Home position shift distance
Home position address
parameter No.PC07
Proximity dog
3ms or less
Note. Configure a sequence that changes the point table selection earlier, considering the delay time of CC-Link communication.
The parameter No.PC07 (home position return position data) setting value is the positioning address after
the home position return is completed.