15 - 29
15. COMMUNICATION FUNCTION
15.5.6 Disable/enable of I/O devices (DIO)
Inputs can be disabled independently of the I/O devices ON/OFF. When inputs are disabled, the input signals
(devices) are recognized as follows. Among the input devices, EMG, LSP and LSN cannot be disabled.
Signal Status
Input devices (DI)
OFF
(1) Disabling/enabling the input devices (DI) with the exception of EMG, LSP and LSN.
Transmit the following communication commands.
(a) Disable
Command Data
No.
Data
[9][0] [0][0]
1EA5
(b) Enable
Command Data
No.
Data
[9][0] [1][0]
1EA5
(2) Disabling/enabling the output devices (DO)
Transmit the following communication commands.
(a) Disable
Command Data
No.
Data
[9][0] [0][3]
1EA5
(b) Enable
Command Data
No.
Data
[9][0] [1][3]
1EA5