16 - 77
16. INDEXER POSITIONING OPERATION
(5) Using absolute position detection system
Parameter
Initial
value
Unit Setting
range
No. Symbol
Name
PA03 *ABS Absolute position detection system
0000h
Refer to the text.
POINT
This parameter is made valid when power is switched off, then on after
setting.
Set this parameter when using the absolute position detection system.
Selection of absolute position detection system (refer to section 16.10)
0: Used in incremental system
1: Used in absolute position detection system
Parameter No.PA03
0 0 0
(6) Servo motor speed setting unit selection
Parameter
Initial
value
Unit Setting
range
No. Symbol
Name
PA05 *FTY Feeding function selection
0000h
Refer to the text.
POINT
This parameter is made valid when power is switched off, then on after
setting.
Select setting units for the servo motor speed.
0
0
0
Parameter No. PA05
Servo motor speed setting unit selection
0: 1r/min unit
1: 0.1r/min unit
Setting to "1" will be as follows.
The setting value of the servo motor speed will be limited to 6553.5r/min.
The "Servo motor speed" status will be displayed as 0.1r/min unit.
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...