17 - 53
17. SPEED CONTROL OPERATION
No.
Symbol
Name and function
Initial
value
Unit
Setting
Range
PC39 Not used in speed control operation.
0
PC40
Do not change the parameter.
PC41 For manufacturer setting
0000h
PC42
Do not change this value by any means.
0000h
PC43
0000h
PC44
0000h
PC45 Not used in speed control operation.
0000h
PC46
Do not change the parameter.
0000h
PC47
0000h
PC48 For manufacturer setting
0000h
PC49
Do not change this value by any means.
0000h
PC50
*COPA Function selection C-A
0
0
CC-Link communication error (A8D)
extension function selection
0: No extension function
1: CC-Link communication error (A8D) detection delay
Use parameter No. PD25 to set how long to delay the
occurrence timing of the CC-Link communication
error (A8D).
Setting of this digit is available with servo amplifiers
with software version A8 or later.
Remote register speed command data reflection
timing selection
0: Reflecting at the rising edge of the Speed command
execution demand (RY(n + 2)1)
1: Always reflecting while the Position command
execution demand (RY(n + 2)1) is on
When this parameter is set using MR Configurator with software version C5
or earlier, the parameter name is not displayed. However, the setting value is
changeable. Follow the instructions in this Instruction Manual to set the
value.
0000h Refer
to
the
Name
and
function
column.
(3) Alarm history clear
Use the MR Configurator or MR-PRU03 parameter module to check the alarm history. The servo amplifier
stores the latest six alarm events after its first power-on. To manage the alarm history in the actual operation,
clear the alarm history using parameter No.PC18 (Alarm history clear) before starting operation. The setting
of the parameter will be enabled when the power is cycled. After the alarm history is cleared, parameter
No.PC18 (Alarm history clear) is set back to "
0" automatically.
0 0 0
Parameter No.PC18
Alarm history clear
0: Invalid (not cleared)
1: Valid (cleared)
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...