6 - 26
6. PARAMETERS
No. Symbol
Name and function
Initial value
Unit
Setting range
PC23
For manufacturer setting
Do not change this value by any means.
0000h
PC24 *COP3 Function selection C-3
Select the unit of the in-position range.
In-position range unit selection
0: Command input unit
1: Servo motor encoder unit
0 0 0
0000h Refer
to
name and
function
column.
PC25
For manufacturer setting
Do not change this value by any means.
0000h
PC26 *COP5 Function selection C-5
Select the stroke limit warning (A99).
Stroke limit warning (A99) selection
0: Valid
1: Invalid
When this parameter is set to "1", A99 will not
occur if the forward rotation stroke end (LSP) or
reverse rotation stroke end (LSN) turns OFF.
0 0 0
0000h Refer
to
name and
function
column.
PC27
For manufacturer setting
Do not change this value by any means.
0000h
PC28 *COP7 Function selection C-7
Select the display method of the current position and command position.
Electronic gear fraction clear selection
0: Invalid
1: Valid
By setting it to "1", the fraction of the last command
by the electronic gear is cleared when starting
automatic operation.
0 0
Current position and command position display
selection
0000h Refer to
name and
function
column.
Setting
value
Display
method
Operation
mode
Status display
Current position
Command position
0 Positioning
display
Automatic The actual current
position where the
machine home
position is assumed
as 0 is displayed.
The command current
position where the
machine home
position is assumed
as 0 is displayed.
Manual
1 Roll
feed
display
Automatic The actual current
position where the
automatic operation
start position is
assumed as 0 is
displayed.
The count starts from
0 when the start signal
is turned on, and the
command current
position to the target
position is displayed.
During a stop, the
command position of
the selected point
table is displayed.
Manual
The command
position of the
selected point table is
displayed.
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...