4 - 3
4. SIGNALS AND WIRING
Wire the power supply and main circuit as shown below so that the servo-on (RYn0) turns off as soon as alarm
occurrence is detected and power is shut off.
A no-fuse breaker (MCCB) must be used with the input cables of the power supply.
(1) For 3-phase 200 to 230VAC power supply to MR-J3-10T to MR-J3-350T
EMG
ALM
D
C
U
V
W
U
V
W
2
3
4
1
M
Motor
24VDC
OFF
MC
ON
MCCB
RA
MC
DOCOM
DOCOM
Malfunction
SK
MC (Note 7)
Servo amplifier
CNP1
L
1
L
2
L
3
N( )
P
1
P
2
CNP2
P( )
L
11
L
21
(Note 2)
(Note 1)
CN2
PE
CNP3
(Note 5)
Servo motor
Encoder
CN6
CN6
DICOM
(Note 4)
(Note 4)
(Note 3)
Encode cable
3-phase
200 to
230VAC
Forced stop
(Note 6)
Malfunction
RA
Forced stop
(Note 6)
Note 1. Always connect P
1
and P
2
. (Factory-wired.) When using the power factor improving DC reactor, refer to section 14.11.
2. Always connect P( ) and D. (Factory-wired.) When using the regenerative option, refer to section 14.2.
3. For encoder cable, use of the option cable is recommended. Refer to section 14.1 for selection of the cable.
4. For the sink I/O interface. For the source I/O interface, refer to section 4.8.3.
5. Refer to section 4.10.
6. Configure the circuit which shuts off main circuit power with external sequence at forced stop (EMG) off.
7. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80ms or less.
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...