
5 - 8
5. OPERATION
5.3 Servo amplifier display
On the servo amplifier display (three-digit, seven-segment display), check the status of communication with the
CC-Link controller at power-on, check the station number, and diagnose a fault at occurrence of an alarm.
(1) Display sequence
Servo amplifier power on
(Note 3)
Waiting for CC-Link communication
CC-Link master module power on
CC-Link communication beginning
When alarm occurs,
alarm code appears.
(Note 3)
Not ready
Servo on
(Note 3)
Ready
Servo amplifier power off
(Note 1)
When alarm warning
No. is displayed
At occurrence of overload
Flicker
display
At occurrence of overload
warning (Note 2)
Flicker
display
During forced stop
Flicker
display
Alarm reset or
warning
Note 1. Only alarm and warning No. are displayed, but no station No. is displayed.
2. If warning other than AE6 occurs during the servo on, flickering the second place of decimal point indicates that it is during the
servo on.
3. The right-hand segments of b01, c02 and d16 indicate the axis number.
(Below example indicates Station No.1)
Station
No.1
Station
No.2
Station
No.64
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...