16 - 27
16. INDEXER POSITIONING OPERATION
(b) Rough match
The following timing charts show the relationships between the signal and the position command
generated in the servo amplifier. This timing can be changed using parameter No.PC11 (rough match
output range). RXn2 turns ON in the servo-on status.
ON
ON
Position command
Rough match (RXn2)
3ms or less
Start (RYn1)
OFF
OFF
When "0" is set in parameter No.PC11
ON
ON
Position command
Rough match (RXn2)
3ms or less
Rough match output range
Start (RYn1)
OFF
OFF
When more than "0" is set in parameter No.PC11
(c) In position
The following timing chart shows the relationship between the signal and the feedback pulse of the
servo motor. This timing can be changed using parameter No.PA10 (in-position range). turns on RYn1
in the servo-on status.
0r/min
ON
ON
Servo motor
speed
In position (RXn1)
3ms or less
In-position range
Start (RYn1)
OFF
OFF
Forward
rotation
When positioning operation is performed once