1 - 18
1. FUNCTIONS AND CONFIGURATION
(2) MR-J3-200TN MR-J3-200T4 or less
Occupied station count switch (SW1)
Switch for manufacturer setting (SW2)
5
4
3
2
1
0
9
8
7
6
MODE
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
X10 S TATION NO. X1
SW1
SW2
Name/Application
Detailed
explanation
Display
The 3-digit, seven-segment LED shows the servo
status and alarm number.
Section 5.3
Chapter 11
Baud rate switch (MODE)
Select the CC-Link communication baud rate.
Section 3.2.4
Station number switches (STATION NO.)
Set the station number of the servo amplifier.
Set the one place.
Set the ten place.
Section 3.2.3
Set the number of occupied stations.
Do not change the default setting (left).
Section 3.2.5
Main circuit power supply connector (CNP1)
Used to connect the input power supply.
Section 4.1
Section 4.3
Section 12.1
Communication alarm display section
Indicates alarms in CC-Link communication.
L.RUN
SD
RD
L.ERR
Section 11.3
USB communication connector (CN5)
Used to connect the personal computer.
Chapter 7
RS-422 communication connector (CN3)
Used to connect the MR-PRU03 parameter unit or
personal computer.
Chapter 7
Chapter 8
Chapter 15
CC-Link connector (CN1)
Wire the CC-Link cable.
Section 3.2.2
I/O signal connector (CN6)
Used to connect digital I/O signals.
Section 4.2
Section 4.4
Encoder connector (CN2)
Used to connect the servo motor encoder.
Section 4.10
Section 14.1
Battery connector (CN4)
Used to connect the battery for absolute position data
backup.
Section 5.8
Section 14.7
Control circuit connector (CNP2)
Used to connect the control circuit power supply/
regenerative option.
Section 4.1
Section 4.3
Section 12.1
Section 14.2
Servo motor power output connector (CNP3)
Used to connect the servo motor.
Section 4.1
Section 4.3
Section 12.1
Battery holder
Contains the battery for absolute position data backup.
Section 5.8
Charge lamp
Lit to indicate that the main circuit is charged. While
this lamp is lit, do not reconnect the cables.
Protective earth (PE) terminal ( )
Grounding terminal.
Section 4.1
Section 4.3
Section 12.1
Rating plate
Section 1.4
Fixed part
(3 places)
Cooling fan
(Note)
5
3
2
0
8
7
5
3
2
0
8
7
5
3
2
0
8
7
Note. Connectors (CNP1, CNP2, and CNP3) and appearance of MR-J3-200T servo amplifier have been changed from January 2008
production. Model name of the existing servo amplifier is changed to MR-J3-200T-RT. For MR-J3-200T-RT, refer to appendix 5.
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...