1 - 31
1. FUNCTIONS AND CONFIGURATION
(5) MR-J3-350T4 MR-J3-500T(4)
R S T
L
21
P
1
P
2
CN5
CN3
CN2
CN4
CN6
L
11
U V W
C
P
L
1
L
2
L
3
CC-Link
CN1
(Note 2)
(Note 1)
Battery
MR-J3BAT
Servo motor
I/O signal
Servo amplifier
Regenerative option
MR Configurator
(Note 3)
Power supply
Molded-case circuit
breaker (MCCB)
Magnetic
contactor
(MC)
Line noise
filter
(FR-BLF)
(Note 2)
Power factor
improving DC
reactor
(FR-BEL-(H))
Personal
computer
Note 1. The battery (option) is used for the absolute position detection system in the position control mode.
2. The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
When not using power factor improving DC reactor, short P
1
and P
2
.
3. Refer to section 1.2 for the power supply specification.