5 - 92
Chapter 5 Data Used for Positioning Control
Storage item
Storage details
Reading the monitor value
Starting history (U
p to 16 rec
ords can be
stored)
[Md.3]
Start
information
[Storage details]
This area stores the start information (restart flag, start origin, and start
axis):
Restart flag: Indicates whether the operation has or has not been
halted and restarted.
Start origin : Indicates the source of the start signal.
Start axis : Indicates the started axis.
Refresh cycle: At start
[Reading the monitor value]
Monitoring is carried out with a hexadecimal display.
Not used
0 0 0 0 0
b15
b12
b8
b4
b0
Buffer
memory
Monitor
value
PLC CPU
Stored contents
Storage value
00
01
10
External signal
GX Works2
Start origin
Restart flag OFF
0
1
Restart flag ON
Restart flag
Start axis
Stored contents
Storage value
Storage value
5
3
1
2
4
10
Stored contents
Axis 1
Axis 2
Axis 3
Axis 4
Axis 5
Axis 16
[Md.4]
Start No.
The starting No. is stored.
Refresh cycle: At start
Monitoring is carried out with a hexadecimal display.
Simultaneous start
JOG operation
Machine HPR
Manual pulse generator
Fast HPR
Current value changing
b15
b12
b8
b4
b0
B
A
C
D
Buffer
memory
Monitor value
Positioning operation
Stored contents
Storage value
Reference
(Decimal)
Start No.
A
0
0
0
to
B
C
D
1
001
2
3
2
C
9004
2
3
3
2
9010
2
3
3
3
9011
2
3
2
9
9001
2
3
2
A
9002
2
3
2
B
9003
1
B
5
8
0
2
5
8
7000
1
B
5
9
7001
1
B
5
A
7002
1
B
5
B
7003
1
B
5
C
7004
600
Synchronous control operation
2
3
3
C
9020
Position control mode
speed control mode switching
Position control mode
torque control mode switching
Speed control mode
torque control mode switching
Torque control mode
speed control mode switching
Speed control mode
position control mode switching
Torque control mode
position control mode switching
2
3
4
6
9030
2
3
4
7
9031
2
3
4
8
9032
2
3
4
9
9033
2
3
4
A
9034
2
3
4
B
9035
2
3
4
C
9036
Outside the range of control mode setting
Note: If a start signal is issued against an operating axis, a record relating to this event may be output before a record
relating to an earlier start signal is output.
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......