5 - 46
Chapter 5 Data Used for Positioning Control
[Pr.84] Restart allowable range when servo OFF to ON
(1) Restart function at switching servo OFF to ON
The restart function at switching servo OFF to ON performs continuous
positioning operation (positioning start, restart) when switching servo OFF to
ON while the Simple Motion module is stopped (including forced stop, servo
forced stop).
Restart at switching servo OFF to ON can be performed when the difference
between the last command position of Simple Motion module at stop and the
present value at switching servo OFF to ON is equal to or less than the value
set in the buffer memory for the restart allowable range setting.
(a) Servo emergency stop processing
1) When the difference between the last command position of Simple
Motion module at the forced stop input or the servo forced stop input
and the present value at the forced stop release or the servo forced
stop release is equal to or less than the value set in the buffer
memory for the restart allowable range setting, the positioning
operation is judged as stopped and can be restarted.
2) When the difference between the last command position of Simple
Motion module at the forced stop input or the servo forced stop input
and the present value at the forced stop release or the servo forced
stop release is greater than the value set in the buffer memory for the
restart allowable range setting, the positioning operation is judged as
on-standby and cannot be restarted.
Operation
Servo OFF
Last command position
Servo ON
Stop/Wait
Restart invalid
Restart valid
Axis operation
status
Forced stop
Release
Input
Release
(b) Processing at switching the servo ON signal from OFF to ON
1) When the difference between the last command position of Simple
Motion module at switching the servo ON signal from ON to OFF and
the present value at switching the servo ON signal from OFF to ON
is equal to or less than the value set in the buffer memory for the
restart allowable range setting, the positioning operation is judged as
stopped and can be restarted.
2) When the difference between the last command position of Simple
Motion module at switching the servo ON signal from ON to OFF and
the present value at switching the servo ON signal from OFF to ON
is greater than the value set in the buffer memory for the restart
allowable range setting, the positioning operation is judged as on-
standby and cannot be restarted.
Stop command
Servo ON
Stop/Wait
Restart invalid
Restart valid
Axis operation status
Stop
Positioning
Servo OFF
ON
OFF
Servo ON signal
Md.108
( Servo status: b1)
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......