5 - 40
Chapter 5 Data Used for Positioning Control
[Pr.28] Deceleration time 1 to [Pr.30] Deceleration time 3
These parameters set the time for the speed to decrease from the "[Pr.8] Speed
limit value" ("[Pr.31] JOG speed limit value" at JOG operation control) to zero
during a positioning operation.
[Pr.31] JOG speed limit value
Set the maximum speed for JOG operation.
Note) Set the "JOG speed limit value" to a value less than "[Pr.8] Speed limit
value".
If the "speed limit value" is exceeded, the error "JOG speed limit value error"
(error code: 956) will occur.
[Pr.1] setting value
Value set with GX Works2
(unit)
Value set with sequence program
(unit)
0 : mm
0.01 to 20000000.00 (mm/min)
1 to 2000000000 (
10
-2
mm/min)
1 : inch
0.001 to 2000000.000 (inch/min)
1 to 2000000000 (
10
-3
inch/min)
2 : degree
0.001 to 2000000.000 (degree/min)
1
1 to 2000000000 (
10
-3
degree/min)
2
3 : PLS
1 to 1000000000 (PLS/s)
1 to 1000000000 (PLS/s)
1: The JOG speed limit value setting range is 0.001 to 2000000.000[degree/min], but it will be
decupled and become 0.01 to 20000000.00[degree/min] by setting "[Pr.83] Speed control 10 x
multiplier setting for degree axis" to valid.
2: The JOG speed limit value setting range is 1 to 2000000000(
10
-3
degree/min), but it will be
decupled and become 1 to 2000000000 (
10
-2
degree/min) by setting "[Pr.83] Speed control 10 x
multiplier setting for degree axis" to valid.
[Pr.32] JOG operation acceleration time selection
Set which of "acceleration time 0 to 3" to use for the acceleration time during JOG
operation.
0: Use value set in "[Pr.9] Acceleration time 0".
1: Use value set in "[Pr.25] Acceleration time 1".
2: Use value set in "[Pr.26] Acceleration time 2".
3: Use value set in "[Pr.27] Acceleration time 3".
[Pr.33] JOG operation deceleration time selection
Set which of "deceleration time 0 to 3" to use for the deceleration time during JOG
operation.
0: Use value set in "[Pr.10] Deceleration time 0".
1: Use value set in "[Pr.28] Deceleration time 1".
2: Use value set in "[Pr.29] Deceleration time 2".
3: Use value set in "[Pr.30] Deceleration time 3".
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......