12 - 17
Chapter 12 Expansion Control
Stop cause during torque control mode
The operation for stop cause during torque control mode is shown below.
Item
Operation during torque control mode
"[Cd.180] Axis stop" turned ON.
The speed limit value commanded to servo amplifier is "0"
regardless of the setting value of "[Cd.146] Speed limit value at
torque control mode". The mode switches to the position control
mode when "Zero speed" of "[Md.108] Servo status" turns ON,
and the operation immediately stops. (Deceleration processing
is not executed.)
The value of command torque is not changed. It might take time
to reach the speed "0" depending on the current torque
command value.
Stop signal of "[Cd.44] External input
signal operation device" turned ON.
All axis servo ON [Y1] turned OFF.
The servo OFF is not executed during the torque control mode.
The command status when the mode is switched to the position
control mode becomes valid.
"[Cd.100] Servo OFF command" turned
ON.
The current value reached the software
stroke limit.
An error (error code: 507, 508, 104, 105, or 101) occurs. The
mode switches to the position control mode at the current
position, and the operation immediately stops. (Deceleration
processing is not executed.)
The position of the motor reached the
hardware stroke limit.
PLC READY [Y0] turned OFF.
The forced stop input to Simple Motion
module.
The mode switches to the position control mode when the servo
OFF (Servo ON of "[Md.108] Servo status" turns OFF) is
executed.
(While the servo amplifier is servo OFF, even if the mode is
switched to position control mode, the servomotor immediately
stops.
The emergency stop input to servo
amplifier.
The servo alarm occurred.
The servo amplifier's power supply
turned OFF.
The motor immediately stops. (The mode is set to the position
control mode at the servo amplifier's power supply ON again.)
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......