11 - 28
Chapter 11 Manual Control
11.4.2 Manual pulse generator operation execution procedure
The manual pulse generator operation is carried out by the following procedure.
Write "1" in " Manual pulse generator enable
flag", and operate the manual pulse generator.
Cd.21
Create a sequence program in which the enable
/disable is set for the manual pulse generator
operation. (" Manual pulse generator
enable flag" setting.)
Cd.21
Set the parameters.
One of the following two methods can be used.
<Method 1>
Directly set (write) the parameters in the Simple Motion
module using GX Works2.
<Method 2>
Set (write) the parameters from the PLC CPU to the Simple
Motion module using the sequence program.
STEP 1
Preparation
End of control
STEP 2
STEP 3
STEP 4
Monitor using GX Works2.
STEP 5
STEP 6
Create a sequence program in which the
" Manual pulse generator 1 pulse input
magnification" is set. (Control data setting)
Cd.20
End the input from the manual pulse generator,
and issue a command to disable the manual
pulse generator operation.
Monitor the manual pulse generator operation.
Issue a command to enable the manual pulse
generator operation, and input the signals from
the manual pulse generator.
Write the sequence program created in STEP1
and STEP2 to the PLC CPU.
Cd.21
Stop operating the manual pulse generator, and write "0"
in " Manual pulse generator enable flag".
Manual pulse
generator operation
start
Manual pulse
generator operation
stop
Monitoring of the
manual pulse
generator operation
Refer to Chapter 5
and Section 11.4.3.
Refer to Section
11.4.4.
( to , )
Pr.1
Pr.24
Pr.89
REMARK
Mechanical elements such as limit switches are considered as already installed.
Parameter settings work in common for all control using the Simple Motion module.
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......