11 - 18
Chapter 11 Manual Control
11.3.2 Inching operation execution procedure
The inching operation is carried out by the following procedure.
Set the parameters.
( to )
Pr.1
Pr.31
One of the following two methods can be used.
<Method 1>
Directly set (write) the parameters in the Simple Motion
module using GX Works2.
<Method 2>
Set (write) the parameters from the PLC CPU to the Simple
Motion module using the sequence program.
STEP 1
Preparation
Refer to Chapter 5
and Section 11.3.3.
End of control
STEP 2
Refer to Section
11.3.4.
STEP 3
STEP 4
Monitor using GX Works2.
STEP 5
Write the sequence program created in STEP1
and STEP2 to the PLC CPU.
Turn ON the JOG start signal of the axis to be
started.
Monitoring of the
inching operation
STEP 6
Turn OFF the JOG start signal that is ON.
Monitor the inching operation status.
Refer to Chapter 6.
Inching operation
start
Inching operation
stop
End the inching operation after moving a workpiece
by an inching movement amount with the sequence
program created in STEP 2.
Create a sequence program in which the "JOG
start signal" is turned ON by an inching
operation start command.
Create a sequence program in which the
" Inching movement amount" is set.
(Control data setting)
Cd.16
Turn ON the JOG start signal.
Forward run JOG
start signal
Reverse run JOG
start signal
QD77GF
Cd.181 Forward run
JOG start
Cd.182 Reverse run
JOG start
REMARK
Mechanical elements such as limit switches are considered as already installed.
Parameter settings work in common for all control using the Simple Motion module.
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......