11 - 25
Chapter 11 Manual Control
Restricted items
A manual pulse generator is required to carry out manual pulse generator
operation.
Precautions during operation
The following details must be understood before carrying out manual pulse
generator operation.
(1) The speed during manual pulse generator operation is not limited by the
"[Pr.8] Speed limit value".
(2) If "[Cd.21] Manual pulse generator enable flag" is turned ON while the Simple
Motion module is BUSY (BUSY signal ON), the warning "Start during
operation" (warning code: 100) will occur.
(3) If a stop factor occurs during manual pulse generator operation, the operation
will stop, and the BUSY signal will turn OFF.
At this time, "[Cd.21] Manual pulse generator enable flag" will remain ON.
However, manual pulse generator operation will not be possible. To carry out
manual pulse generator operation again, measures must be carried out to
eliminate the stop factor. Once eliminated, the operation can be carried out
again by turning "[Cd.21] Manual pulse generator enable flag" ON
OFF
ON.
(Note that this excludes hardware/software stroke limit error.)
(4) Command will not be output if an error occurs when the manual pulse
generator operation starts.
Important
The speed command is issued according to the input from the manual pulse
generator irrelevant of the speed limit setting.
When the speed command is larger than 62914560pps (63Mpps), the servo alarm
"Command frequency error" (alarm No.: 35) will occur.
The following calculation formula is used to judge whether or not a servo alarm will
occur.
(Speed command) =
Manual pulse
generator 1
pulse input
magnification
Manual pulse
generator 1
pulse movement
amount
Number of pulses per rotation
Movement amount per rotation
Number of
input pulses
for one
second
If a large value is set to the manual pulse generator 1 pulse input magnification,
there is a high possibility of the servo alarm "Command frequency error" (alarm
No.: 35) occurrence. Note that the servomotor does not work rapidly by rapid pulse
input even if the servo alarm will not occur.
REMARK
One Simple Motion module can be connected to one manual pulse generator.
The QD77GF module can simultaneously command to multiple servo amplifiers by
one manual pulse generator.
(Simultaneous operation is possible up to the maximum number of control axes.)
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......