5 - 83
Chapter 5 Data Used for Positioning Control
[Da.11] Shape
Set whether to carry out only the local "block start data" and then end control, or to
execute the "block start data" set in the next point.
Setting value
Setting details
0 : End
Execute the designated point's "block start data", and then complete the control.
1 : Continue
Execute the designated point's "block start data", and after completing control, execute the next
point's "block start data".
[Da.12] Start data No.
Set the "positioning data No." designated with the "block start data".
[Da.13] Special start instruction
Set the "special start instruction" for using "high-level positioning control". (Set how
to start the positioning data set in "[Da.12] Start data No.".)
Setting value
Setting details
00H: Block start
(Normal start)
Execute the random block positioning data in the set order with one start.
01H: Condition start
Carry out the condition judgment set in "condition data" for the designated positioning data, and
when the conditions are established, execute the "block start data". If not established, ignore
that "block start data", and then execute the next point's "block start data".
02H: Wait start
Carry out the condition judgment set in "condition data" for the designated positioning data, and
when the conditions are established, execute the "block start data". If not established, stop the
control (wait) until the conditions are established.
03H: Simultaneous
start
Simultaneous execute (output command at same timing) the positioning data with the No.
designated for the axis designated in the "condition data".
Up to four axes can start simultaneously.
04H: Repeated start
(FOR loop)
Repeat the program from the block start data with the "FOR loop" to the block start data with
"NEXT" for the designated number of times.
05H: Repeated start
(FOR condition)
Repeat the program from the block start data with the "FOR condition" to the block start data
with "NEXT" until the conditions set in the "condition data" are established.
06H: NEXT start
Set the end of the repetition when "04H: Repetition start (FOR loop)" or "05H: Repetition start
(FOR condition)" is set.
Refer to Chapter 10 "High-Level Positioning Control" for details on the control.
[Da.14] Parameter
Set the value as required for "[Da.13] Special start instruction".
[Da.13] Special start instruction
Setting value
Setting details
Block start (Normal start)
–
Not used. (There is no need to set.)
Condition start
1 to 10
Set the condition data No. (Data No. of
"condition data" is set up for the
condition judgment.)
Wait start
Simultaneous start
Repeated start (FOR loop)
0 to 255
Set the number of repetitions.
Repeated start (FOR condition)
1 to 10
Set the condition data No. (Data No. of
"condition data" is set up for the
condition judgment.)
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......