16 - 51
Chapter 16 Troubleshooting
Related buffer memory address
Set range
(Setting with sequence program)
Remedy
— —
Give a request at the position where there is an
enough remaining distance.
4346+100n
<Step start information>
1: Step is continued
2: Re-start is carried out
Do not set a "1" to the step start information when the
step is not in standby state. (Refer to Section 13.7.1)
62+150n
<External command function selection>
0, 1, 2, 3, 4
Set the detailed parameter 2 "External command
function selection" to within the setting range.
Refer to Section 5.3
"List of positioning data"
—
Set a decelerating address or a movement amount to
the positioning data.
New speed value
<New speed value>
0 to 1000000000 [PLS/s]
0 to 2000000000 [ 10
-2
mm/min or another]
• Set the speed change value to within the setting
range.
• Set "[Cd.140] Command speed at speed control
mode" to within the setting range during the speed
control mode.
• Set "[Cd.146] Speed limit value at torque control
mode" to within the setting range during the torque
control mode.
4314+100n
4315+100n
Position-speed switching control
speed change register
<Position-speed switching control speed
change register>
0 to 1000000000 [PLS/s]
0 to 2000000000 [ 10
-2
mm/min or another]
4330+100n
4331+100n
Target position change value
(New speed)
<Target position change value
(New speed)>
0 to 1000000000 [PLS/s]
0 to 2000000000 [ 10
-2
mm/min or another]
4336+100n
4337+100n
Command speed at speed control
mode
<Command speed at speed control mode>
-1000000000 to 1000000000 [PLS/s]
-2000000000 to 2000000000
[ 10
-2
mm/min or another]
4376+100n
4377+100n
Speed limit value at torque control
mode
<Speed limit value at torque control mode>
0 to 1000000000 [PLS/s]
0 to 2000000000 [ 10
-2
mm/min or another]
4384+100n
4385+100n
4349+100n
<Teaching positioning data No.>
1 to 600
Set the positioning data No. to within the setting range.
4348+100n
<Teaching data selection>
0, 1
Set the teaching data selection set value to within the
setting range.
n: Axis No.-1
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......