8 - 16
Chapter 8 HPR Control
Precautions during operation
(1) The error "Start at HP" (error code: 201) will occur if another machine HPR is
attempted immediately after a machine HPR completion when the HP is in the
proximity dog ON position.
(2) The following shows the operation when a machine HPR is started from the
proximity dog ON position.
Zero signal
Proximity dog
Pr.46 HPR speed
Pr.47 Creep speed
HPR direction
Pr.44
ON
1)
2)
V
3)
OFF
Hardware limit switch
[Operation when a machine HPR is started
from the proximity dog ON position]
1) The machine moves in the opposite direction
against of HPR at the HPR speed.
2) The machine begins decelerating when the
first zero signal is detected.
3) After deceleration stop, the operation moves in
direction of HPR at the creep speed, and then
stops at the zero signal to complete the
machine HPR.
POINT
After 1), when the zero signal is in the proximity
dog ON position, deceleration stop (2)) is started
at the zero signal without waiting for the proximity
dog OFF.
Fig. 8.11 Operation when a machine HPR is started from the proximity dog ON position
(3) When the stop signal stops the machine HPR, carry out the machine HPR
again. When restart command is turned ON after the stop signal stops the
HPR, the error "HPR restart not possible" (error code: 209) will occur.
(4) The HPR retry will not be performed regardless of setting set in "[Pr.48] HPR
retry" in the scale origin signal detection method. When a hardware limit
switch is detected during machine HPR, the error "Hardware stroke limit (+)"
(error code: 104) or "Hardware stroke limit (-)" (error code: 105) will occur.
(5) Position the proximity dog forward to overlaps with the hardware limit switch in
direction of HPR. When the proximity dog is in the opposite direction against
of HPR from the machine HPR start position, the error "Hardware stroke limit
(+)" (error code: 104) or "Hardware stroke limit (-)" (error code: 105) will occur.
Machine HPR
Proximity dog
Hardware limit switch
HP
M
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......