10 - 14
Chapter 10 High-Level Positioning Control
10.3.7 Repeated start (FOR condition)
In a "repeated start (FOR condition)", the data between the "block start data" in which
"5: FOR condition" is set in "[Da.13] Special start instruction" and the "block start data"
in which "6: NEXT start" is set in "[Da.13] Special start instruction" is repeatedly
executed until the establishment of the conditions set in the "condition data".
Conditional judgment is carried out as soon as switching to the point of "6: NEXT start"
(before positioning of NEXT start point).
(The "condition data" designation is set in "[Da.14] Parameter" of the "block start data"
in which "5: FOR condition" is set in "[Da.13] Special start instruction".)
Section [2] shows a control example where the "block start data" and "positioning data"
are set as shown in section [1].
[1] Setting examples
(1) Block start data setting example
Axis 1 block
start data
[Da.11]
Shape
[Da.12]
Start data No.
[Da.13]
Special start
instruction
[Da.14]
Parameter
1st point
1: Continue
1
5: FOR condition
5
2nd point
1: Continue
10
0: Block start
–
3rd point
0: End
50
6: NEXT start
–
(Note): The "condition data Nos." have been set in "[Da.14] Parameter".
(2) Positioning data setting example
Axis 1 positioning
data No.
[Da.1]
Operation pattern
1
01: Continuous positioning control
2
01: Continuous positioning control
3 00:
Positioning
complete
10
11: Continuous path control
11 00:
Positioning
complete
50
01: Continuous positioning control
51 00:
Positioning
complete
[2] Control examples
The following shows the control executed when the "block start data" of the 1st
point of axis 1 is set as shown in section [1] and started.
<1> Execute axis 1 "positioning data No.1, 2, 3, 10, and 11".
<2> Carry out the conditional judgment set in axis 1 "condition data No.5"
(Note-1)
.
Conditions not established
Execute "Positioning data No.50, 51".
Go to <1>.
Conditions established
Execute "Positioning data No.50, 51" and
complete the positioning.
(Note-1): Conditional judgment is carried out as soon as switching to NEXT start
point (before positioning of NEXT start point).
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......