13 - 47
Chapter 13 Control Sub Functions
(5) The warning "Deceleration/stop speed change" (warning code: 500) occurs
and the speed cannot be changed in the following cases.
During deceleration by a stop command
During automatic deceleration during positioning control
(6) The warning "Speed limit value over" (warning code: 501) occurs and the
speed is controlled at the "[Pr.8] Speed limit value" when the value set in
"[Cd.14] New speed value" is larger than the "[Pr.8] Speed limit value".
(7) When the speed is changed during interpolation control, the required speed
is set in the reference axis.
(8) When carrying out consecutive speed changes, be sure there is an interval
between the speed changes of 100ms or more.
(If the interval between speed changes is short, the Simple Motion module
will not be able to track, and it may become impossible to carry out
commands correctly.)
(9) When a speed change is requested simultaneously for multiple axes, change
the speed one by one.
Therefore, the start timing of speed change is different for each axis.
(10) Speed change cannot be carried out during the machine HPR. A request for
speed change is ignored.
(11) When deceleration is started by the speed change function, the deceleration
start flag does not turn ON.
(12) The speed change function cannot be used during speed control mode or
torque control mode. Refer to Section 12.1 "Speed-torque control" for the
speed change during speed control mode.
[3] Setting the speed change function from the PLC CPU
The following shows the data settings and sequence program example for
changing the control speed of axis 1 from the PLC CPU. (In this example, the
control speed is changed to "20.00mm/min".)
(1) Set the following data.
(Use the speed change time chart shown in section (2) below as a reference,
and set using the sequence program shown in section (3).)
Setting item
Setting
value
Setting details
Buffer memory address
[Cd.14]
New speed value
2000 Set the new speed.
4314+100n
4315+100n
[Cd.15]
Speed change
request
1
Set "1: Change the speed".
4316+100n
n: Axis No.-1
: Refer to Section 5.7 "List of control data" for details on the setting details.
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......