5 - 75
Chapter 5 Data Used for Positioning Control
When "[Pr.1] Unit setting" is "mm"
The table below lists the control methods that require the setting of the arc
address and shows the setting range.
(With any control method excluded from the table below, the arc address does not
need to be set.)
[Da.2] setting value
Value set with GX Works2
(
m)
Value set with sequence program 1
(
10
-1
m)
ABS circular sub
: 0DH
ABS circular right
: 0FH
ABS circular left
: 10H
Set the address
-214748364.8 to 214748364.7 2
Set the address
-2147483648 to 2147483647
INC circular sub
: 0EH
INC circular right
: 11H
INC circular left
: 12H
Set the movement amount
-214748364.8 to 214748364.7 2
Set the movement amount
-2147483648 to 2147483647 2
1: Set an integer because the sequence program cannot handle fractions.
(The value will be converted properly within the system.)
2: Note that the maximum radius that circular interpolation control is possible is 536870912 (
10
-1
m), although the
setting value can be input within the range shown in the above table, as an arc address.
When "[Pr.1] Unit setting" is "degree"
No control method requires the setting of the arc address by "degree".
When "[Pr.1] Unit setting" is "PLS"
The table below lists the control methods that require the setting of the arc
address and shows the setting range.
(With any control method excluded from the table below, the arc address does not
need to be set.)
[Da.2] setting value
Value set with GX Works2
(PLS)
Value set with sequence program 1
(PLS)
ABS circular sub
: 0DH
ABS circular right
: 0FH
ABS circular left
: 10H
Set the address
-2147483648 to 2147483647 1
Set the address
-2147483648 to 2147483647
INC circular sub
: 0EH
INC circular right
: 11H
INC circular left
: 12H
Set the movement amount
-2147483648 to 2147483647 1
Set the movement amount
-2147483648 to 2147483647 1
1: Note that the maximum radius that circular interpolation control is possible is 536870912 (PLS), although the setting
value can be input within the range shown in the above table, as an arc address.
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......