9 - 18
Chapter 9 Major Positioning Control
9.1.5 Control unit "degree" handling
When the control unit is set to "degree", the following items differ from when other
control units are set.
[1] Feed current value and feed machine value addresses
The address of "[Md.20] Feed current value" becomes a ring address from 0 to
359.99999°. The address of "[Md.21] Feed machine value" will become a
cumulative value. (They will not have a ring structure for values between 0 and
359.99999°.) However, "[Md.21] Feed machine value" is restored with cumulating
the feed machine value before the power supply OFF (the rounded value within
the range of 0 to 359.99999°) to the movement amount during the power supply
OFF at the communication start with servo amplifier after the power supply ON or
PLC CPU reset.
0°
0°
0°
359.99999°
359.99999°
[2] Software stroke limit valid/invalid setting
With the control unit set to "degree", the software stroke limit upper and lower
limit values are 0 to 359.99999°.
(a) Setting to validate software stroke limit
To validate the software stroke limit, set the software stroke limit lower limit
value and the upper limit value in a clockwise direction.
Section A
Section B
315.00000
90.00000
Clockwise direction
0
1) To set the movement range A, set as follows.
• Software stroke limit lower limit value .................................. 315.00000°
• Software stroke limit upper limit value ................................... 90.00000°
2) To set the movement range B, set as follows.
• Software stroke limit lower limit value .................................... 90.00000°
• Software stroke limit upper limit value ................................. 315.00000°
(b) Setting to invalidate software stroke limit
To invalidate the software stroke limit, set the software stroke limit lower
limit value equal to the software stroke limit upper limit value.
The control can be carried out irrespective of the setting of the software
stroke limit.
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......