14 - 4
Chapter 14 Common Functions
[3] Precautions during control
(1) Parameter initialization is only executed when the positioning control is not
carried out (when the PLC READY signal [Y0] is OFF).
The warning "In PLC READY" (warning code: 111) will occur if executed
when the PLC READY signal [Y0] is ON.
(2) Writing to the flash ROM is up to 100,000 times. If writing to the flash ROM
exceeds 100,000 times, the writing may become impossible, and the error
"Flash ROM write error" (error code: 801) will occur.
(3) A "PLC CPU reset" or "PLC CPU power restart" must be carried out after
the parameters are initialized.
(4) If an error occurs on the parameter set in the Simple Motion module when
the PLC READY signal [Y0] is turned ON, the READY signal [X0] will not be
turned ON and the control cannot be carried out.
Important
Parameter initialization takes about 16 seconds. (Up to 30 seconds are sometimes
required.)
Do not turn the power ON/OFF or reset the PLC CPU during parameter
initialization. If the power is turned OFF or the PLC CPU module is reset to forcibly
end the process, the data backed up in the flash ROM/internal memory
(nonvolatile) will be lost.
[4] Parameter initialization method
(1) Parameter initialization is carried out by the writing of the data shown in the
table below to the buffer memory of Simple Motion module using the TO
command/intelligent function device.
The initialization of the parameter is executed at the time point the data is
written to the buffer memory of Simple Motion module.
Setting item
Setting
value
Setting details
Buffer memory
address
[Cd.2]
Parameter
initialization
request
1
Set "1: Requests parameter initialization.".
5901
: Refer to Section 5.7 "List of control data" for details on the setting details.
When the initialization is complete, "0" will be set in "[Cd.2] Parameter
initialization request" by the Simple Motion module automatically.
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......