5 - 38
Chapter 5 Data Used for Positioning Control
5.2.4 Detailed parameters 2
Item
Setting value, setting range
Default
value
Buffer memory address
Value set with GX Works2
Value set with sequence
program
[Pr.25] Acceleration time 1
1 to 8388608 (ms)
1 to 8388608 (ms)
1000
36+150n
37+150n
[Pr.26] Acceleration time 2
38+150n
39+150n
[Pr.27] Acceleration time 3
40+150n
41+150n
[Pr.28] Deceleration time 1
42+150n
43+150n
[Pr.29] Deceleration time 2
44+150n
45+150n
[Pr.30] Deceleration time 3
46+150n
47+150n
[Pr.31]
JOG speed limit value
The setting range differs depending on the "[Pr.1] Unit setting".
20000
48+150n
49+150n
[Pr.32]
JOG operation acceleration
time selection
0: [Pr.9] Acceleration time 0
0
0 50+150n
1: [Pr.25] Acceleration time 1
1
2: [Pr.26] Acceleration time 2
2
3: [Pr.27] Acceleration time 3
3
[Pr.33]
JOG operation deceleration
time selection
0: [Pr.10] Deceleration time 0
0
0 51+150n
1: [Pr.28] Deceleration time 1
1
2: [Pr.29] Deceleration time 2
2
3: [Pr.30] Deceleration time 3
3
[Pr.34]
Acceleration/deceleration
process selection
0: Trapezoid acceleration/
deceleration process
0
0 52+150n
1: S-curve acceleration/
deceleration process
1
[Pr.35]
S-curve ratio
1 to 100 (%)
1 to 100 (%)
100
53+150n
[Pr.36]
Rapid stop deceleration
time
1 to 8388608 (ms)
1 to 8388608 (ms)
1000
54+150n
55+150n
[Pr.37]
Stop group 1 rapid stop
selection
0: Normal deceleration stop
0
0
56+150n
[Pr.38]
Stop group 2 rapid stop
selection
57+150n
1: Rapid stop
1
[Pr.39]
Stop group 3 rapid stop
selection
58+150n
[Pr.40]
Positioning complete signal
output time
0 to 65535 (ms)
0 to 65535 (ms)
0 to 32767
: Set as a
decimal
32768 to 65535 : Convert into
hexadecimal
and set
300 59+150n
n: Axis No.-1
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......