5 - 160
Chapter 5 Data Used for Positioning Control
Setting item
Setting details
[Cd.180] Axis stop
When the axis stop signal turns ON, the HPR control, positioning control, JOG
operation, inching operation, manual pulse generator operation, speed-torque
control, etc. will stop.
By turning the axis stop signal ON during positioning operation, the positioning
operation will be "stopped".
Whether to decelerate stop or rapidly stop can be selected with "[Pr.39] Stop
group 3 rapid stop selection".
During interpolation control of the positioning operation, if the axis stop signal of
any axis turns ON, all axes in the interpolation control will decelerate and stop.
Fetch cycle: Operation cycle
[Cd.181] Forward run JOG start
When the JOG start signal is ON, JOG operation will be carried out at the "[Cd.17]
JOG speed
". When the JOG start signal turns OFF, the operation will decelerate
and stop.
When inching movement amount is set, the designated movement amount is
output for one operation cycle and then the operation stops.
Fetch cycle: Operation cycle
[Cd.182] Reverse run JOG start
[Cd.183] Execution prohibition flag
If the execution prohibition flag is ON when the positioning start signal turns ON,
positioning control does not start until the execution prohibition flag turns OFF.
Used with the "Pre-reading start function". (Refer to Section 13.7.7)
Fetch cycle: At start
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......