5 - 14
Chapter 5 Data Used for Positioning Control
[2] Monitoring the axis operation state
Monitoring the position
Monitor details
Corresponding item
Monitor the current feed machine value.
[Md.21]
Feed machine value
Monitor the current "feed current value".
[Md.20]
Feed current value
Monitor the current target value.
[Md.32]
Target value
Monitoring the speed
Monitor details
Corresponding item
Monitor the
current
speed.
During independent axis control
Indicates
the speed
of each
axis.
[Md.22]
Feedrate
During
interpolation
control
When "0:
Composite speed" is set for
"[Pr.20] Interpolation speed
designation method"
Indicates
the
composit
e speed.
When "1:
Reference axis speed" is
set for "[Pr.20] Interpolation
speed designation method"
Indicates
the
reference
axis
speed.
Monitor "[Da.8] Command speed" currently being
executed.
[Md.27]
Current speed
Constantly indicates the speed of each axis.
[Md.28]
Axis feedrate
Monitor the current target speed.
[Md.33]
Target speed
Monitor the command speed at speed control mode in the speed-
torque control.
[Md.122] Speed during command
Monitoring the status of servo amplifier
Monitor details
Corresponding item
Monitor the real current value (feed current value - deviation
counter).
[Md.101]
Real current value
Monitor the droop pulse.
[Md.102]
Deviation counter value
Monitor the motor speed of servo motor.
[Md.103]
Motor rotation speed
Monitor the current value of servo motor.
[Md.104]
Motor current value
Monitor the parameter No. that an error occurred.
[Md.107]
Parameter error No.
Monitor the status (servo status) of servo amplifier.
[Md.108]
Servo status
Monitor the percentage of regenerative power to permissible
regenerative value.
[Md.109]
Regenerative load ratio
Monitor the continuous effective load torque.
[Md.110]
Effective load torque
Monitor the maximum generated torque.
[Md.111]
Peak torque ratio
Monitor the status of semi closed loop control/fully closed loop
control.
[Md.113]
Semi/Fully closed loop status
Monitor the alarm of servo amplifier.
[Md.114]
Servo alarm
Monitor the CiA402 Statusword of servo amplifier.
[Md.117]
Statusword [CiA402 mode]
Monitor the HPR operating status of servo amplifier.
[Md.514]
HPR operating status [CiA402 mode]
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......