13 - 40
Chapter 13 Control Sub Functions
[4] When the hardware stroke limit function is not used
When not using the hardware stroke limit function, set the logic of FLS and RLS
to the "negative logic" (initial value) with "[Pr.22] Input signal logic selection" and
input the signal which always turns ON. Otherwise, set the logic of FLS and RLS
to the "positive logic" with "[Pr.22] Input signal logic selection" and always turn
OFF the input.
[5] Servo parameter setting [CiA402 mode]
Set "Sensor input type selection" of the servo parameter "Function selection D-4
(PD41)" properly at MR-J4-GF use. Otherwise, the stroke limit signal cannot be
released. The operation at stroke limit detection according to each setting is as
follows.
Control
details
Controller setting
[Pr.80] External input signal
selection
Servo parameter setting
Sensor input type selection of
Function selection D-4 (PD41)
Actual signal
input
Stop process
Other than
HPR
1: External input signal of
servo amplifier
0: Input from servo amplifier
Servo amplifier
–
*1
Controller
*3
1: Input from controller
Servo amplifier
–
*1
2: Buffer memory of
QD77GF
0: Input from servo amplifier
Servo amplifier
–
*1
Controller
–
*1
1: Input from controller
Servo amplifier
–
*2
Controller Controller
HPR
1: External input signal of
servo amplifier
0: Input from servo amplifier
Servo amplifier
Servo amplifier
1: Input from controller
Servo amplifier
–
*1
2: Buffer memory of
QD77GF
0: Input from servo amplifier
Servo amplifier
–
*1
Controller
–
*1
1: Input from controller
Servo amplifier
–
*2
Controller Servo
amplifier
1 : The error "Servo parameter PD41 setting error" (error code: 1005) occurs. The cyclic transmission is not
performed.
2 : The stroke limit signal cannot be released.
3 : When "1: Enabled only for HPR mode" is set to "Stroke limit enabling condition selection" of the servo
parameter "Function selection D-4 (PD41)"
POINT
The consistency between "[Pr.80] External input signal selection" and the servo
parameter "Function selection D-4 (PD41)" is checked at the start of connection
with the servo amplifier. At the diagnostic error, the error "Servo parameter PD41
setting error" (error code: 1005) occurs and the cyclic transmission with the servo
amplifier of the target axis is not performed.
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......