12 - 13
Chapter 12 Expansion Control
Stop cause during speed control mode
The operation for stop cause during speed control mode is shown below.
Item
Operation during speed control mode
"[Cd.180] Axis stop" turned ON.
The motor decelerates to speed "0" according to
the setting value of "[Cd.142] Deceleration time at
speed control mode". The mode switches to the
position control mode when "Zero speed" of
"[Md.108] Servo status" turns ON, and the
operation stops.
Stop signal of "[Cd.44] External input signal
operation device" turned ON.
All axis servo ON [Y1] turned OFF.
The servo OFF is not executed during the speed
control mode. The command status when the mode
is switched to the position control mode becomes
valid.
"[Cd.100] Servo OFF command" turned ON.
The current value reached the software stroke limit. An error (error code: 507, 508, 104, 105, or 101)
occurs. The mode switches to the position control
mode at the current position, and the operation
immediately stops. (Deceleration processing is not
executed.)
The position of the motor reached the hardware
stroke limit.
PLC READY [Y0] turned OFF.
The forced stop input to Simple Motion module.
The mode switches to the position control mode
when the servo OFF (Servo ON of "[Md.108] Servo
status" turns OFF) is executed. (While the servo
amplifier is servo OFF, even if the mode is switched
to position control mode, the servomotor
immediately stops.
The emergency stop input to servo amplifier.
The servo alarm occurred.
The servo amplifier's power supply turned OFF.
The motor immediately stops. (The mode is set to
the position control mode at the servo amplifier's
power supply ON again.)
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......