5 - 88
Chapter 5 Data Used for Positioning Control
[Da.18] Parameter 1
Set the parameters as required for the "[Da.16] Condition operator" and "[Da.23]
Number of simultaneous starting axes".
[Da.16] Condition operator
[Da.23] Number of
simultaneous
starting axes
Setting value
Setting details
01H :
=P1
Value
The value of P1 should be equal to or smaller than the
value of P2. (P1
P2)
If P1 is greater than P2 (P1>P2), the error "Condition
data error" (error code 533) will occur.
02H :
P1
03H :
P1
04H :
P1
05H : P1
P2
06H :
P1, P2
07H : DEV=ON
Value
(bit No.)
Set the device bit No.
X: 0H to 1H, 10H to 1FH Y: 0H, 1H, 10H to 1FH
08H : DEV=OFF
2 to 4
Value
(positioning data
No.)
Set the positioning data No. for starting axis set in
"[Da.24] Simultaneous starting axis No.1" and/or
"[Da.25] Simultaneous starting axis No.2".
Low-order 16-bit : Simultaneous starting axis
No.1 positioning data No.1 to
600 (01H to 258H)
High-order 16-bit : Simultaneous starting axis
No.2 positioning data No.1 to
600 (01H to 258H)
[Da.19] Parameter 2
Set the parameters as required for the "[Da.16] Condition operator" and "[Da.23]
Number of simultaneous starting axes".
[Da.16] Condition operator
[Da.23] Number of
simultaneous
starting axes
Setting value
Setting details
01H :
=P1
—
Not used. (No need to be set.)
02H :
P1
03H :
P1
04H :
P1
05H : P1
P2
Value
The value of P2 should be equal to or greater than the
value of P1. (P1
P2)
If P1 is greater than P2 (P1>P2), the error "Condition
data error" (error code 533) will occur.
06H :
P1, P2
07H : DEV=ON
—
Not used. (No need to be set.)
08H : DEV=OFF
2 to 3
4
Value
(positioning data
No.)
Set the positioning data No. for starting axis set in
"[Da.26] Simultaneous starting axis No.3"
Low-order 16-bit : Simultaneous starting axis
No.3 positioning data No. 1 to
600 (01H to 258H)
High-order 16-bit : Not used (Set "0")
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......