9 - 50
Chapter 9 Major Positioning Control
Positioning data setting example
[When "2-axis fixed-feed control (fixed-feed 2)" is set in positioning data No. 1 of
axis 1]
• Reference axis ............. Axis 1
• Interpolation axis.......... Axis 2 (The required values are also set in positioning
data No. 1 of axis 2.)
Axis
Setting item
Setting example
Setting details
Axis 1
(reference
axis)
Axis 2
(interpolation
axis)
A
xi
s 1
P
os
iti
oni
ng dat
a No.
1
[Da.1]
Operation pattern
Positioning
complete
–
Set "Positioning complete" assuming the next
positioning data will not be executed.
[Da.2]
Control method
Fixed-feed 2
–
Set 2-axis fixed-feed control.
[Da.3]
Acceleration time No.
1
–
Designate the value set in "[Pr.25]
Acceleration time 1" as the acceleration time
at start.
[Da.4]
Deceleration time No.
0
–
Designate the value set in "[Pr.10]
Deceleration time 0" as the deceleration time
at deceleration.
[Da.6]
Positioning address/
movement amount
8000.0
m 6000.0
m
Set the positioning address. (Assuming "mm"
is set in "[Pr.1] Unit setting".)
[Da.7]
Arc address
–
–
Setting not required (setting value is ignored).
[Da.8]
Command speed
6000.00
mm/min
–
Set the speed during movement. (Designate
the composite speed of reference axis speed
in "[Pr.20] Interpolation speed designation
method".)
[Da.9]
Dwell time/JUMP
destination positioning
data No.
500ms –
Set the time the machine dwells after the
positioning stop (command stop) to the output
of the positioning complete signal.
[Da.10]
M code/Condition data
No./Number of LOOP
to LEND repetitions
10 –
Set this when other sub operation commands
are issued in combination with the No. 1
positioning data.
[Da.20]
Axis to be interpolated
No.1
Axis 2
–
Set the axis to be interpolated.
If the self-axis is set, an error will occur.
[Da.21]
Axis to be interpolated
No.2
– –
Setting not required (setting value is ignored).
[Da.22]
Axis to be interpolated
No.3
– –
(Note): Refer to Section 5.3 "List of positioning data" for information on the setting details.
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......