9 - 85
Chapter 9 Major Positioning Control
Operation chart
The following chart shows the operation timing for 4-axis speed control with axis 1
as the reference axis.
The "in speed control" flag ([Md.31] Status: b0) is turned ON during speed control.
The "positioning complete signal" is not turned ON.
t
V
BUSY signal
[X10, X11, X12, X13]
OFF
ON
Positioning start signal
[Y10]
OFF
ON
OFF
OFF
ON
Does not turn ON even
when control is stopped
by stop command.
OFF
ON
Reference axis (axis 1)
t
V
Interpolation axis (axis 3)
t
V
Command speed
Da. 8
Interpolation axis (axis 4)
t
V
Interpolation axis (axis 2)
Command speed
Da. 8
Command speed
Da. 8
Command speed
Da. 8
( Md.31 Status:b0)
In speed control flag
Positioning complete signal
( Md.31 Status:b15)
Cd.180 Axis stop
Fig. 9.12 4-axis speed control operation timing
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......