11 - 5
Chapter 11 Manual Control
Important
Use the hardware stroke limit function when carrying out JOG operation near the
upper or lower limits. (Refer to Section "13.4.4".)
If the hardware stroke limit function is not used, the workpiece may exceed the
moving range, causing an accident.
Precautions during operation
The following details must be understood before carrying out JOG operation.
(1) For safety, first set "[Cd.17] JOG speed" to a smaller value and check the
movement. Then gradually increase the value.
(2) The error "Outside JOG speed range" (error code: 300) will occur and the
operation will not start if the "JOG speed" is outside the setting range at the
JOG start.
(3) The error "JOG speed limit value error" (error code: 956) will occur and the
operation will not start if "[Pr.31] JOG speed limit value" is set to a value larger
than "[Pr.8] Speed limit value".
(4) If "[Cd.17] JOG speed" exceeds the speed set in "[Pr.31] JOG speed limit
value", the workpiece will move at the "[Pr.31] JOG speed limit value" and the
warning "JOG speed limit value" (warning code: 301) will occur in the Simple
Motion module.
(5) The JOG operation can be continued even if an "Axis warning" has occurred.
(6) Set a "0" in "[Cd.16] Inching movement amount". If a value other than "0" is set,
the operation will become an inching operation (Refer to Section 11.3 "Inching
operation").
Operations when stroke limit error occurs
When the operation is stopped by hardware stroke limit error or software stroke
limit error, the JOG operation can execute in an opposite way (direction within
normal limits) after an error reset. (An error will occur again if JOG start signal is
turned ON in a direction to outside the stroke limit.)
JOG operation possible
JOG operation not possible
Upper/lower
limit signal
JOG operation
V
ON
OFF
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......