13 - 6
Chapter 13 Control Sub Functions
(3) Setting the dwell time during an HPR retry
The HPR retry function can perform such function as the dwell time using
"[Pr.57] Dwell time during HPR retry" when the reverse run operation is
carried out due to detection by the limit signal for upper and lower limits and
when the machine HPR is executed after the proximity dog is turned OFF to
stop the operation.
"[Pr.57] Dwell time during HPR retry" is validated when the operation stops
at the "A" and "B" positions in the following drawing. (The dwell time is the
same value at both positions "A" and "B".)
Hardware limit switch
Limit signal OFF
Stop by limit
signal detection
A
HP
Machine HPR start
Reverse run operation
after limit signal detection
Stop by proximity
dog OFF
Proximity dog
Zero signal
Machine HPR
executed again
Pr. 44
B
HPR direction
Fig. 13.3 Setting the dwell time during an HPR retry
[2] Precaution during control
(1) The following table shows whether the HPR retry function may be executed
by the "[Pr.43] HPR method".
[Pr.43] HPR method
Execution status of HPR retry function
Proximity dog method
[RJ010 mode]
: Execution possible
Count method 1)
: Execution possible
Count method 2)
: Execution possible
Data set method
Scale origin signal detection method
: Execution not possible
Driver HPR method
[CiA402 mode]
(2) Always establish upper/lower limit switches at the upper/lower limit positions
of the machine. If the HPR retry function is used without hardware stroke
limit switches, the motor will continue rotation until a hardware stroke limit
signal is detected.
(3) Do not configure a system so that the servo amplifier power turns OFF by
the upper/lower limit switches. If the servo amplifier power is turned OFF,
the HPR retry cannot be carried out.
(4) The operation decelerates upon detection of the hardware limit signal, and
the movement starts in the opposite direction. In this case, however, the
error "Hardware stroke limit (+)" (error code: 104) or "Hardware stroke limit (-
)" (error code: 105) does not occur.
Содержание MELSEC Q Series
Страница 1: ...MELSEC Q QD77GF Simple Motion Module User s Manual Positioning Control QD77GF4 QD77GF8 QD77GF16 ...
Страница 2: ......
Страница 30: ...A 28 MEMO ...
Страница 32: ...MEMO ...
Страница 97: ...3 29 Chapter 3 Specifications and Functions MEMO ...
Страница 102: ...3 34 Chapter 3 Specifications and Functions MEMO ...
Страница 282: ...5 162 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 374: ...7 16 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 376: ...MEMO ...
Страница 400: ...8 24 Chapter 8 HPR Control MEMO ...
Страница 425: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 528: ...9 128 Chapter 9 Major Positioning Control MEMO ...
Страница 554: ...10 26 Chapter 10 High Level Positioning Control MEMO ...
Страница 586: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 800: ...16 54 Chapter 16 Troubleshooting MEMO ...
Страница 829: ...Appendix 29 Appendices 3 QD77GF16 Unit mm inch 115 4 53 3 0 12 23 0 91 27 4 1 08 98 3 86 4 0 16 ...
Страница 830: ...Appendix 30 Appendices MEMO ...
Страница 833: ......