background image

Содержание RPCM DC 232A

Страница 1: ......

Страница 2: ...es of Operation 24 4 Description of the RPCM Device 25 4 1 Physical Interface 26 4 2 Web Interface of RPCM 37 4 3 RPCM SSH Interface 51 4 4 Input Operation 58 4 5 Outlet Operation 67 4 6 RPCM Configur...

Страница 3: ...es 250 6 6 Command show Information about the Status of RPCM 252 6 7 Command show all 275 6 8 Command set 287 6 9 Command set output 311 6 10 Command set automation 316 6 11 Command start 325 6 12 Com...

Страница 4: ...ways physically ergonomically architecturally electrically it is designed to be one stop shop for many power control tasks that people meet in many circumstances We have made every effort to make RPC...

Страница 5: ...current 232 for RPCM DC 232A Outlets 10 outlets designed for a current of 30A with a 4 mm2 cross section 24A with a cross sec tion of 2 5 mm2 wires Overconsumption protection with individual configur...

Страница 6: ...utomated power cut off on the outlet where consumption exceeding the defined limits was de tected Customizable outlet activation sequence and delays to start up services correctly after complete power...

Страница 7: ...is in any case recorded in the system log Then depending on what type of notification was configured the user will get a notification about the event If the SNMP Trap option is configured the correspo...

Страница 8: ...ent Power Control Module RPCM 2 2 Mounting onto rack detailed instructions for preparing for installing and connecting the Resilient Power Control Module RPCM 2 3 Mounting RPCM 3x250 and RPCM DELTA th...

Страница 9: ...NTION If any abnormal situation occurs please contact technical support Do not attempt to open or repair the Resilient Power Control Module RPCM yourself Repairs should be carried out only by a qualif...

Страница 10: ...uit protection parameters Overload protection ad justable 0 1 30A default 30A short circuit protection tripping current 87 5A Overload protection adjustable 0 1 30A default 30A short cir cuit protecti...

Страница 11: ...standard 19 cabinet occupies 1U Operating temperature 0 40 0 40 Storage temperature 20 60 20 60 Relative air humidity 45 85 no condensation 45 85 no condensation Contacts of technical support for the...

Страница 12: ...es or circuit breakers for disconnection in case of danger Note In order to protect outlets from short circuits short circuit protection selectivity has to be ensured in the electrical design For RPCM...

Страница 13: ...tion operating range of altitude above sea level is 0 2000 m 2 2 5 Checking the Packaging Before unpacking the boxes ensure that they do not have dents cuts stains and other damages due to incorrect h...

Страница 14: ...2 Installing RPCM Figure 2 2 1 Inserting rack nuts Figure 2 2 2 Mounting the Resilient Power Control Module RPCM 14...

Страница 15: ...erminals of RPCM DC ATS 76A and RPCM DC 232A have significant differences in design dimensions and cross sectional area of wires These differences originate from the difference in maximum current valu...

Страница 16: ...Before inserting wire into terminal you must first open the clamp To do this insert a screw driver into the rectangular shaft near the clamp To disconnect you must also insert a screwdriver into the...

Страница 17: ...C 232A 2 2 7 3 Connection of conductors to RPCM DC ATS 76A and RPCM DC 232A output clamp terminals RPCM DC uses clamp terminals to connect power wires to supply power to loads To connect the conductor...

Страница 18: ...2 Installing RPCM Figure 2 2 7 Connecting the conductor to the RPCM DC ATS 76A or RPCM DC 232A outlet terminal 18...

Страница 19: ...ormation about the available IP and MAC addresses and the procedure for assign ing IP addresses using various methods 3 2 System Requirements System requirements for input power supply for the Resilie...

Страница 20: ...rnet ports for RPCM DC 232A In order to avoid accidental skipping of the desired message press and release the top or the bot tom button The result will appear on the screen within 5 seconds Switching...

Страница 21: ...vice The alternative is to manually configure IP addresses and subnet mask It is also referred to as IPv4LL IPv4 Link Local Note When using this method of network address configuration IP is automatic...

Страница 22: ...on individual outlets you should choose circuit breakers on input that have tripping delay 2 ms or longer 3 2 2 Computer Requirements for Administration A physical cable with an RJ45 connector for con...

Страница 23: ...eries The power is provided from the input with higher voltage At equal voltage the power comes from both inputs In fact this is a logical OR circuit that supplies power from a source that has a highe...

Страница 24: ...t Operation A description of how to configure outlets to power equipment con nected to RPCM 4 6 RPCM Configuration Management A description of the Resilient Power Control Module general configuration...

Страница 25: ...LED display in the center of the device on the front panel The left part of the display shows the device s system information about the device the right part displays inputs and outlets statuses On t...

Страница 26: ...control button 3 LED display 4 input indicator 1 5 input indicator 2 6 outlet indicators 0 9 7 Ethernet control port Figure 4 1 2 Rear side of RPCM DC ATS 76A Legend 1 outlets 2 outlet indicators 3 in...

Страница 27: ...gure 4 1 3 Front panel with indicators and controls RPCM DC 232A Legend 1 top control button 2 bottom control button 3 display 4 input indicator 5 outlet indicators 0 9 6 Ethernet control port Figure...

Страница 28: ...lay special code sequences during service Below is the name and sequence of the value demonstration by pressing the controls the top or bottom buttons on the case Table 4 1 1 Display messages Name of...

Страница 29: ...ton The values will be displayed in re verse order except for the message RPCM has started It is possible to reset the system to factory settings To reset to factory settings you must press the top bu...

Страница 30: ...stratively and in fact turned on but the load is not connected red the output was disconnected due to input overload overcurrent short circuit at the output overvoltage at the output accompanied by ap...

Страница 31: ...RPCM Device Figure 4 1 5 Appearance of the model RPCM DC ATS 76A with an active display Front panel shown on top rear panel shown at the bottom Figure 4 1 6 Appearance of the model RPCM DC 232A with...

Страница 32: ...he user it is displayed in red The list of messages View Mode is presented in table 4 1 1 Switching between messages in the view mode occurs by pressing the top or bottom buttons The bottom button swi...

Страница 33: ...administrative shutdown of the 1st pin Accordingly after its activation the function of administrative activation Outlet 1 Switch ON becomes available The list of available functions and correspondin...

Страница 34: ...the object the message suggests to turn off the output administratively 4 1 3 6 General RPCM Control Order in Control Mode Operations All switching between functions and objects is performed by single...

Страница 35: ...N inlet 1 or 2 Regular Enabling input with the number N only for models with ATS perations with the output Outlet N OC Switch OFF N Outlet 0 9 Troubleshooting Switch off the outlet when it was turned...

Страница 36: ...ult username is rpcmadmin the default password is rpcmpassword RPCM s web interface supports various models and versions of browsers such as Chrome from version 61 0 3163 100 official build Safari fro...

Страница 37: ...t are located in the same network segment and are currently available 4 2 2 Description of the Control Panel Dashboard Two modes are available in Dashboard View Mode to visually inform about the statu...

Страница 38: ...ranges red there is no voltage on this input gray input is administratively disabled yellow the voltage of the input is outside the specified limits blinking from green blue red to yellow no grounding...

Страница 39: ...face 4 2 4 Top Control Bar This panel is intended for displaying general information and switching between modes of oper ation Figure 4 2 4 Control elements on the Top Control Bar Legend 1 menu button...

Страница 40: ...otal current consumption in milliamperes total power consumption in watts Figure 4 2 5 Block of information about input status in View Mode Legend 1 number of the inlet 2 inlet voltage scale 3 instant...

Страница 41: ...number 2 outlet name 3 status message 4 instant current value 5 current consumption scale 6 time scale for all graphs 7 graph of current 8 graph of power consumption 9 power consumption scale 10 insta...

Страница 42: ...Do not leave the console unattended with the Control Mode turned on Figure 4 2 7 Dashboard in Control Mode for RPCM DC ATS 76A 4 2 8 Management of inputs in Control Mode For the inputs in Control Mode...

Страница 43: ...kly in the rack 6 instant input current value milliamps 7 instant input active power consumption value watts 4 2 9 Management of Outlets in Control Mode For outlets the following controls can be used...

Страница 44: ...all outlets on or turn all outlets off or reset all outlets with buttons TURN ALL OUTPUTS ON TURN ALL OUTPUTS OFF and RESET ALL OUTPUTS respectively Figure 4 2 10 Control elements for all outlets in C...

Страница 45: ...o an encrypted HTTPS connection Figure 4 2 12 A warning about an insecure connection 4 2 13 Web Interface differences for Models RPCM DC 232A There are some differences in appearance of the web interf...

Страница 46: ...to the maximum values appeared during the time interval shown on the graph Sometimes to evaluate actual usage of current flowing through the RPCM as well as voltage on different channels you might wa...

Страница 47: ...button again to have graphs dis played with the scales set according to the required configuration Figure 4 2 16 Show Limits settings RPCM DC with ATS for input 2 Legend 1 inlet number 2 voltage limit...

Страница 48: ...of the outlet 2 name of the outlet 3 instant current consumption value milliamps 4 current alarm limit value 5 current alarm limit switch 6 current turn off limit value 7 current turn off limit switch...

Страница 49: ...4 Description of the RPCM Device Figure 4 2 18 The Dashboard control panel in the Show Limits mode 49...

Страница 50: ...quivalent ssh ip_address Note If you are using other systems and software such as PUTTY consult the relevant documen tation In the RPCM system SSH access uses authentication based on username and pass...

Страница 51: ...short circuit condition Output 1 Outlet 1 is in the state of overload according to the set parameters Output 2 Outlet 2 is in operating mode under load Output 3 Outlet 3 is in operating mode under loa...

Страница 52: ...working order and the energy is consumed blue outlet switched on but the energy is not consumed red outlet was switched off due to short circuit overcurrent on output overcurrent on input or overvolt...

Страница 53: ...ow inputs outputs snmp etc information version show system software version and system time quit command line interface Type help to get suggestions To get information on each individual command you m...

Страница 54: ...e make input active available on RPCM1502 RPCM1532 current limit set total input current limit description set input description frequency limit set input frequency limits max top value min bottom val...

Страница 55: ...off output number 0 9 set output 0 9 on turn on output number 0 9 set output 0 9 recognition set output 0 9 recognition state off to off on to on set output 0 9 overcurrent tune overcurrent limits ala...

Страница 56: ...CM without ATS have only one input for example RPCM DC 232A RPCM without ATS does not have the ability to disable enable a single input In other aspects of its management via SSH CLI it is similar to...

Страница 57: ...ion using the menu entry Inputs or by typing https name_or_IP_RPCM inputs in the browser address line provided that authentication was pre viously successful Figure 4 4 1 Inputs section is selected in...

Страница 58: ...k to visit the RPCM product site rpcm pro 4 light identification button depicted as a lightbulb image 5 sound identification button depicted as a radio image 6 Unlock Control button depicted as a lock...

Страница 59: ...see the following groups of values INFORMATION contains the following data Name user settable input name Description comment field up to 255 characters long Active indicator of whether the input is ac...

Страница 60: ...section When you click on the top text information area to the right of the chart a pop up window will be opened to set the parameters of the first input if you click on the bottom information area th...

Страница 61: ...te Input 2 is configured in the same way 4 4 6 Management of Inlets in Control Mode Figure 4 4 6 Control Mode of the Input Section Legend 1 inlet number 2 instant input voltage value 3 TURN ON button...

Страница 62: ...ith Name Description and Recognition state 9 LIMITS block with the thesholds 10 gear button to call the INPUT SETTINGS pop up window 11 COUNTERS block with the accumulated power consumption data kWh 4...

Страница 63: ...ge values scales in web interface s graphs are getting automatically ad justed to the maximum values appeared during the time interval shown on the graph Sometimes to evaluate actual usage of current...

Страница 64: ...After enabling Showing Current Limits selected areas of the set limits are turned on for the se lected parameters Figure 4 4 11 The setting items for Showing Current Limits Legend 1 inlet number 2 vol...

Страница 65: ...tant power consumption 9 INFORMATION block 10 LIMITS block with the thresholds 11 gear button to open the INPUT SETTINGS pop up window 12 COUNTERS block with parameters of power consumption Figure 4 4...

Страница 66: ...u can access this section via Outputs menu item or by typing https name_or_IP_RPCM outputs directly in web browser address bar provided that authentication passed successfully before Note Screenshots...

Страница 67: ...4 Description of the RPCM Device 4 5 2 Output Outlets section Figure 4 5 2 Main window of the section Outputs 67...

Страница 68: ...group of service values internal temperature in degrees Celsius time and date 4 5 4 Information Area of the Section Outputs Each area has a graph for the outlet allowing you to get a visual representa...

Страница 69: ...urrent alarm fired TURN OFF LIMIT contains the following data Current mA when this value is exceeded for time longer than duration specified in the next field outlet turn off is triggered Duration s d...

Страница 70: ...tion don t turn on automatically after startup when voltage is applied to the RPCM after a complete shutdown this output will remain off turn on after start up s delay at start up set to avoid high in...

Страница 71: ...s turned off overvoltage turn off limit V maximum permissible overvoltage when exceeded the system turns off the outlet due to overvoltage recover turn on after overvoltage limit s delay in seconds af...

Страница 72: ...on the outlet 4 RESET button use to cycle power on the outlet 5 TURN OFF button use to turn off the outlet 6 IDENTIFY button to turn on recognition blinking on outlet to locate it in the rack 7 insta...

Страница 73: ...ting automatically ad justed to the maximum values appeared during the time interval shown on the graph Sometimes to evaluate actual current flowing through the RPCM on different channels you might wa...

Страница 74: ...owing Current Limits configuration Figure 4 5 9 Showing Current Limits configuration switches for outlet 1 are on Legend 1 number of the outlet 2 instant current consumption value milliamps 3 switch o...

Страница 75: ...ff 5 instant power consumption value watts 6 INFORMATION block 7 COUNTERS block 8 OVERVOLTAGE PROTECTION block 9 ALARM LIMIT block 10 gear button to open the OUTPUT SETTINGS pop up window 11 TURN OFF...

Страница 76: ...ng https name_or_IP_RPCM configuration in the browser address string provided that authentica tion was previously successful Note Screenshots of the RPCM DC 232A are shown as an illustration For other...

Страница 77: ...section main window Control panels can be collapsed to fit all panels on screen for easy navigation Figure 4 6 3 Configuration section with collapsed panels 4 6 3 Top Control Bar in Configuration Sect...

Страница 78: ...configuration section there are the following field for managing common RPCM parame ters Users and Groups user and group management Location and Tech Contact reference information about the location...

Страница 79: ...4 Description of the RPCM Device Figure 4 6 5 Configuration section management panels 79...

Страница 80: ...el Controller is temporarily unavailable connection to the RPCM management interface management via Web SSH SNMP and REST API automation functions will be suspended Power supply short circuit protecti...

Страница 81: ...ap peared window User name the name of the new user Password password Confirm Password confirmation of the password Expiration seconds time in seconds after which the session opened under the user s a...

Страница 82: ...4 6 7 New User pop up window for creating an RPCM system user account To edit an existing account click on the username and the account settings editing window will open Figure 4 6 8 Edit User window...

Страница 83: ...select Local RADIUS the authentication system will try authenticating this user by RADIUS servers If all RADIUS servers unavailable will use fallback to local DB To update user account with new setti...

Страница 84: ...a new group press the ADD button This window serves to fill a group name and set UNIX like permission Read Write eXecute RWX Objects for set permission is following configuration management of RPCM c...

Страница 85: ...RPCM Device Figure 4 6 11 New Group window To create a group click on the CREATE button To cancel use the CANCEL button To edit an existing group click on the groupname and the group settings editing...

Страница 86: ...ndow To update group information with new settings click UPDATE button To cancel changes use the CANCEL button DELETE button is intended to remove the group After clicking DELETE button a confirmation...

Страница 87: ...the device is located Street fill address or other geographic identifier of where this RPCM device is located Room name or number of the room where the device is located Rack coordinates or rack numb...

Страница 88: ...the CANCEL button The Tech Contact tab is intended for specifying technical support details in particular contact number email and name of the company providing support or name of the contact person F...

Страница 89: ...IP Addressing APIPA or IPv4 Link Local IPv4LL or Zero Configuration Networking When using this method of network address configuration IP is auto matically assigned from the range of 169 254 xxx xxx n...

Страница 90: ...window that appears choose Static in Configure IPv4 field and enter static IP address parameters in fields below Figure 4 6 19 The Edit Network Configuration pop up window Red box shows the Configure...

Страница 91: ...to get information and enable disable SNMP agent service 2 MIB files MIB files download links Additional information Management Information Base MIB is a list of data parameters used to manage object...

Страница 92: ...t To do this use the ENABLE SNMP button After activating it a pop up window with a green header with the title Change SNMP agent administrative state will ask you to confirm enabling SNMP Figure 4 6 2...

Страница 93: ...level of security SNMPv1 is still in use thanks to simplicity of implementation SNMP version 2 in the latest revision SNMPv2c also uses Community based Security however owing to the changes intro duc...

Страница 94: ...ive community a name choose whether it will be Read Only or Read Write as well as configure access list to define list of subnets that will be allowed access to this community Subnet format is network...

Страница 95: ...mber of configured records in parentheses Use EDIT button within the record to open the pop up window to make the necessary changes For example set the community entry to Enabled ON Figure 4 6 27 The...

Страница 96: ...me username Access Type either Read only or Read Write Auth Protocol authentication protocol md5 or sha1 Priv Protocol encryption protocol des or aes Access List which IP addresses subnets are allowed...

Страница 97: ...agement panel To create a new SNMPv3 user account use the ADD USER button A New SNMP User pop up window will appear Note Version 0 9 1 of RPCM software include the authPriv authenticate method only Fi...

Страница 98: ...eated If you need to make changes to SNMP user configuration click the EDIT button within the SN MPv3 user record to open Edit SNMP User pop up window Figure 4 6 32 Edit SNMP User window Use DELETE bu...

Страница 99: ...sent to alert the administrator about critical events e g a short circuit outlet turn of due to overcurrent and so on SNMP Trap configuration record has the following attributes SNMP version v1 Desti...

Страница 100: ...ration settings Initially no SNMP trap records are configured SNMP Traps Configuration panel contains the following buttons ADD TRAP to add new SNMP Trap configuration record RELOAD reload settings fr...

Страница 101: ...Time Management Panel The Date Time tab shows current time and time zone It has two fields Date time system time in the YYYY MM DD HH MM SS format Time zone time zone There are two buttons available...

Страница 102: ...into the Device time zone field list of options nar rows down leaving only options matching the entered value When you click on the Device local date field a window opens in calendar format to change...

Страница 103: ...tes and you re all set Figure 4 6 41 Time change pop up window minutes adjustment If the desired minute that you want to set lays between values shown on the clock picture just click area between numb...

Страница 104: ...ed from an other interface like CLI or another browser session Click SYNC NOW button to immediately initiate the time synchronization process with config ured time servers Figure 4 6 43 Pop up window...

Страница 105: ...algorithm CRAM MD5 a method of protecting authentication data based on the MD5 algorithm and NONE no authentica tion performed SSL state following option are available enable sets up encrypted SSL con...

Страница 106: ...pop up window To finalize creation of SMTP server configuration click CREATE button To cancel press CANCEL If you need to change the SMTP server settings click the EDIT in the SMTP server configuratio...

Страница 107: ...tion A confirmation window will appear Figure 4 6 47 Confirmation pop up window Delete SMTP server In the Mail recipients tab you can configure up to 5 e mail recipients records Email recipient record...

Страница 108: ...l open the New recipient pop up window Figure 4 6 49 New recipient pop up window To finalize configuration of the new mail recipient record click the CREATE button To cancel click CANCEL button To del...

Страница 109: ...tomer s fleet of RPCM de vices Cloud Connection Settings panel is intended to control state of the RPCM CLOUD connection There are the following fields and controls in the Cloud Connection tab Cloud s...

Страница 110: ...switch enables disables authentication when using the REST API disabled by default API Key shows the generated API key Key Status this switch enables disables the key enabling API Authentication and s...

Страница 111: ...ssage Voltage Volt V 48 Current Amps A 23 Power Kilowatts KW 1 1 IP Address dotted digits 192 168 1 1 MAC Address hexadecimal digits separated by a colon 68 05 CA 42 EC 22 Serial Name English characte...

Страница 112: ...button named DOWNLOAD CONFIGURATION Clicking DOWNLOAD CONFIGURATION initiates download of backup configuration file The name of the file is RPCM_SerialName_YYYYMMDD_HHMMSS config where SerialName the...

Страница 113: ...ection of options for restore Tese restore options is available Reset to default setting before applying configuration is turning OFF by default Ignore invalid configuration parameters is turning OFF...

Страница 114: ...FIG RESTART RPCM HLC The HLC must be restarted to apply the restored settings After pressing the RESTART RPCM HLC button only the controller will restart The power supply to the connected client devic...

Страница 115: ...ormation setting RADIUS servers Remote Authentication in Dial In User Service use RADIUS protocol for au thentication authorization and data collect about using resources Figure 4 6 62 RADIUS panel Pr...

Страница 116: ...ming group attribute Switch Use incoming session attribute Switch Enabled To enter a new RADIUS server click on the CREATE button To cancel use the CANCEL button Click on RADIUS server record on RADIU...

Страница 117: ...vel Controller HLC which runs Software Low Level Controller LLC which runs Firmware Display Controller which runs Display Firmware Low Level Controller is responsible for low level operations such as...

Страница 118: ...TS for RPCM AC ATS 16A RPCM AC ATS 32A RPCM DC ATS 76A meters overload and short circuit protection Display Controller is responsible for external displays High Level Controller is responsible for the...

Страница 119: ...lds contains the following Model Model Number Serial Name Software version Software release date Firmware version Firmware date Update file selection and process control area contains the following So...

Страница 120: ...help of the CHOOSE FILE buttons operating system file selection window appears During the entire set of update processes status information will be displayed in the window Software update file select...

Страница 121: ...OAD button a copy of the update file is transferred to the RPCM and its subsequently verified In the bottom right corner a pop up window appears with information about the progress of the update and b...

Страница 122: ...e main window Software up date at this stage the PAUSE button changes to UPDATE At this stage the new UPDATE button is inactive and will become active only after the verification procedure is finished...

Страница 123: ...4 Description of the RPCM Device Figure 4 7 6 RPCM is ready to be updated Clicking on the UPDATE button starts the process of installation of the new Software Figure 4 7 7 Applying the update 123...

Страница 124: ...ifying applied update Figure 4 7 8 Verifying an update After successful completion of the update and validation procedure the high level control mod ule needs to be restarted The UPDATE button is chan...

Страница 125: ...ient devices to the RPCM outlets The power is not cut off If you select NO the changes are rolled back You have to update firmware if necessary after a successful reboot of the HLC IMPORTANT for model...

Страница 126: ...oft ware 0 3 27 rpcm Where rpcmsoftware 0 3 27 rpcm is the name of the update file rpcmadmin is the username with administrator rights 192 168 1 28 is the IP address of the updated RPCM device SuperGe...

Страница 127: ...000KW Output 0 ON admin ON 0mA 0W Output 1 ON admin ON 0mA 0W Output 2 ON admin ON 0mA 0W Output 3 ON admin ON 0mA 0W Output 4 ON admin ON 0mA 0W Output 5 ON admin ON 0mA 0W Output 6 ON admin ON 0mA 0...

Страница 128: ...ow Current update status Status Recovery procedure is in progress Progress 5 73 Current update status Status Applying update Progress 14 88 Current update status Status Verifying applied update Progre...

Страница 129: ...SH session manually Restarting High Level Controller in 5 sec onds WARNING If RPCM gets an IP address via DHCP or via Zero Configuration Networking then the IP address after the restart may change To...

Страница 130: ...typing https name_or_IP_RPCM logs in the browser line provided that authentication was suc cessful before Note Screenshots of the RPCM DC 232A are shown as an illustration For other models of RPCM DC...

Страница 131: ...er bar of the System journal Below is a list of items from the Filter bar The field Since the date element is used to set the start date and time from which the log entries are needed Selection menu S...

Страница 132: ...ical error warning warning notice comment about the condition info information message debug information for debugging Figure 4 8 4 Drop down menu for Type of messages The field Include serves to filt...

Страница 133: ...ped are displayed Use the LOAD and RESET buttons to load messages and reset to the original values respectively 4 8 4 Information Window And Bottom Buttons CLEAR and CLOSE The Information window is a...

Страница 134: ...me_or_IP_RPCM netutils in the browser string assuming that authentication was successful before Note Screenshots of the RPCM DC 232A are shown as an illustration For other models of RPCM DC the basic...

Страница 135: ...en pressed the drop down menu is invoked where the command is se lected e g ping Host field for entering the IP address or network name of the device as a parameter of the test command the device name...

Страница 136: ...f the Network Utilities section at the time of the completion of this command and allows you to re execute it if necessary At the bottom of the History area is the control CLEAR upon activation of whi...

Страница 137: ...n Documentation or by typing https name_or_IP_RPCM docs in the browser string provided that authentication was suc cessful before Note Screenshots of the RPCM DC ATS 76A are shown as an illustration F...

Страница 138: ...erations viewing copying a document copying a link to a document are performed in ac cordance with features of the interface and settings of the web browser used For additional in formation please see...

Страница 139: ...principles of working are preserved Figure 4 11 1 Automation item in menu The Automation interface is intended for monitoring various parameters of the connected equipment as well as for rebooting the...

Страница 140: ...sts PING TCP PORT and HASHRATE are performed over a data network RPCM cannot distinguish between device unavailability due to a crash and device unavailability due to scheduled maintenance This should...

Страница 141: ...y clicking on the link it goes to RPCM product site rpcm pro 4 the light identification button in the form of a lightbulb image 5 the sound identification button in the form of a radio image 6 Virtual...

Страница 142: ...of the RPCM Device 4 11 3 Sub sections of the Main Window General Description The main window of the Automation section is divided into 11 subsections Figure 4 11 3 Automation section with numbered su...

Страница 143: ...c parameters of mining this area should be displayed if you set up a special mining device what is supported RPCM Software 9 gear button to open the settings pop up window 10 DEVICE LIST subsection th...

Страница 144: ...ayed name of the monitored device type of device for mining modules description extended comment up to 254 characters 4 11 4 3 Last Reboot and Next Reboot In Figure 4 11 4 this section is marked with...

Страница 145: ...st control Figure 4 11 5 Automation section CONSUMPTION subsection 4 11 4 5 HASHRATE Subsection In Figure 4 11 4 this section is marked with the number 5 It demonstrates basic information about the st...

Страница 146: ...limit GH s the hashrate limit to trigger the restart Restart limit s stabilization delay before triggering restart Restart in progress this field indicates whether restart has been initiated Auto res...

Страница 147: ...e device restart procedure was initiated Last check time time of last control Note The method of calculating the observed loss values for alarms and restarts used in ICMP echo request reply ping tests...

Страница 148: ...lues YES or NO depending on the test results Connection timeout s configured connection timeout after which tcp connection is deemed unavailable Alarm limit s stabilization timeout for alarm Alarm thi...

Страница 149: ...tal Hash Rate 5s GHS number of calculated gigahashes per second last 5s read ing Total Hash Rate AV GHS number of calculated gigahashes per second average value as reported by miner API Below is a des...

Страница 150: ...top right of the subsection to open the pop up editing window Figure 4 11 10 Edit device pop up window There are following buttons at the bottom right corner of the window DELETE CLOSE SAVE SAVE to c...

Страница 151: ...the new watchdog configuration pop up window Clicking on any of the configured devices automatically positions the interface web page on the parameters area of this device Figure 4 11 11 The Device Li...

Страница 152: ...up window with Outputs drop down menu In the Add device pop up window on the left side there are fields for values common to all types of watchdogs Subsection DEVICE includes fields Name watchdog name...

Страница 153: ...scription of the RPCM Device Figure 4 11 13 Pop up window Add device with the called Device type Figure 4 11 14 Selecting Output 8 and Output 9 outputs in the Add Device pop up window with the Output...

Страница 154: ...m of the currents of all the sockets involved Current value mA Alarm limit mA Restart limit for reload mA they all operate with a sum of currents In the MONITORING INTERVAL subsection see Figure 4 11...

Страница 155: ...d TCP port monitoring Figure 4 11 16 Configuring watchdog tests based on consumption and TCP port monitoring To configure consumption monitoring you need to enter parameters in the following fields Co...

Страница 156: ...ation for restart s stabilization delay in seconds for restart Figure 4 11 17 shows the fields for configuration of the watchdogs based on hashrate and Ping ICMP echo request reply monitoring Figure 4...

Страница 157: ...gers an alarm Ping restart packet loss percentage of lost packets top limit which triggers a restart Min duration for alarm s stabilization delay in seconds for alarm Min duration for restart s stabil...

Страница 158: ...hen some tests are combined the load adds up But a large number and high frequency of in spections create an additional load that can interfere with the network and the device being tested In many cas...

Страница 159: ...by using the menu item Documentation or by typing https name_or_IP_RPCM about in the browser if authentication was successful before Figure 4 10 1 Menu to go to the Documentation section This section...

Страница 160: ...st method in the body of URL for HTTP curl X GET http 192 168 1 24 8888 api cachedStatus apikey 373ac3fde3ae0740e0fb76e912e3e18e for HTTPS curl k X GET https 192 168 1 24 8443 api cachedStatus apikey...

Страница 161: ...5 2 1 1 Overview It returns the current status of RPCM in JSON format 5 2 1 2 Get API Status Command GET api status Example curl X GET http 192 168 1 42 8888 api status REPLY rOLC OK sNa OpernyiPevets...

Страница 162: ...Ma 0 iWa 0 aKWh 0 385 channels 0 admS ON actS ON tC ON cbFS OFF oAFS OFF oTFS OFF loTFS OFF rS OFF ovTFS OFF iMa 0 iWa 0 aKWh 0 0 1 admS ON actS ON tC ON cbFS OFF oAFS OFF oTFS OFF loTFS OFF rS OFF ov...

Страница 163: ...Ma 0 iWa 0 aKWh 0 033889 4 admS ON actS ON tC ON cbFS OFF oAFS OFF oTFS OFF loTFS OFF rS OFF ovTFS OFF iMa 0 iWa 0 aKWh 0 0 5 admS ON actS ON tC ON cbFS OFF oAFS OFF oTFS OFF loTFS OFF rS OFF ovTFS OF...

Страница 164: ...FF loTFS OFF rS OFF ovTFS OFF iMa 0 iWa 0 aKWh 0 0 9 admS ON actS ON tC ON cbFS OFF oAFS OFF oTFS OFF loTFS OFF rS OFF ovTFS OFF iMa 0 iWa 0 aKWh 0 0 wE F833006B45 RPCM 1 5 2 1 3 Getting the Cached St...

Страница 165: ...9 rtcB 20100104230141 rtc 20110605150544 r 255 LR 40 R 32 p YES g 150 temp 37 b 0 exB top pr NO ms 1214678712 bottom pr NO ms 1933199992 ats aL 1 gG 0 lines 1 mV 48127 admS ON rS OFF iMa 0 iWa 0 aKWh...

Страница 166: ...F oAFS OFF oTFS OFF loTFS OFF rS OFF ovTFS OFF iMa 0 iWa 0 aKWh 0 350833 name output_1 description restartDelay 10 2 admS ON actS ON tC ON cbFS OFF oAFS OFF oTFS OFF loTFS OFF rS OFF ovTFS OFF iMa 0 i...

Страница 167: ...e output_4 description restartDelay 3 5 admS ON actS ON tC ON cbFS OFF oAFS OFF oTFS OFF loTFS OFF rS OFF ovTFS OFF iMa 0 iWa 0 aKWh 0 0 name output_5 description restartDelay 3 6 admS ON actS ON tC O...

Страница 168: ...28076 0 0 name output_8 description restartDelay 3 9 admS ON actS ON tC ON cbFS OFF oAFS OFF oTFS OFF loTFS OFF rS OFF ovTFS OFF iMa 0 iWa 0 aKWh 0 0 name output_9 description restartDelay 3 wE F8AD00...

Страница 169: ...833 2 0 0 3 0 033889 4 0 0 5 0 0 6 0 0 7 0 0 8 0 0 9 0 0 cbFF 0 0 1 0 2 0 3 0 4 1 5 1 6 0 7 1 8 0 9 0 cOALM 0 8000 1 24000 2 24000 3 24000 4 24000 5 24000 6 24000 7 24000 8 24000 9 9000 cOALS 0 29 1 3...

Страница 170: ...AF 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 cOTLM 0 8000 1 30000 2 30000 3 30000 4 30000 5 30000 6 30000 7 30000 8 30000 9 9500 cOTLS 0 11 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 cOTLR 0 0 1 0 2 0 3 0 4 0...

Страница 171: ...0 8 0 9 0 cAS 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 cTOD 0 3 1 3 2 4 3 5 4 6 5 7 6 8 7 9 8 10 9 11 cTOfIOP 0 7 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 lMiV 1 45 2 90 lMaV 1 51 2 250 lUTA 1 232 2 200 cO...

Страница 172: ...5 4 65535 5 65535 6 65535 7 65535 8 65535 9 65535 laSWMs 1 138642237555 2 138642237555 caSWMs 0 0 1 126366924083 2 0 3 12255947235 4 0 5 0 6 1105525 7 0 8 0 9 18260712 5 2 1 4 Query and Return the Sta...

Страница 173: ...S globalFlagsOfLLC 150 temperature 37 buzzerState 0 externalButtons top pressed NO microseconds 1215148950 bottom pressed NO microseconds 1933670229 ats activeLine 1 groundGood 0 lines 1 millivolts 48...

Страница 174: ...illiamps 0 instantWatts 0 accumulatedKWh 0 350833 name output_1 description restartDelay 10 2 adminState ON actualState ON triggerControl ON circuitBreakerFiredState OFF overcurrentAlarmFiredState OFF...

Страница 175: ...AlarmFiredState OFF overcurrentTurnOffFiredState OFF lineOvercurrentTurnOffFiredState OFF recognitionState OFF overvoltageTurnOffFiredState OFF instantMilliamps 0 instantWatts 0 accumulatedKWh 0 0 nam...

Страница 176: ...F instantMilliamps 0 instantWatts 0 accumulatedKWh 0 0 name output_8 description restartDelay 3 9 adminState ON actualState ON triggerControl ON circuitBreakerFiredState OFF overcurrentAlarmFiredState...

Страница 177: ...0 8 0 0 9 0 0 circuitBreakerFiringFacts 0 0 1 0 2 0 3 0 4 1 5 1 6 0 7 1 8 0 9 0 channelOvercurrentAlarmLimitMilliamps 0 8000 1 24000 2 24000 3 24000 4 24000 5 24000 6 24000 7 24000 8 24000 9 9000 cha...

Страница 178: ...7 0 8 0 9 0 channelOvercurrentTurnOffLimitMilliamps 0 8000 1 30000 2 30000 3 30000 4 30000 5 30000 6 30000 7 30000 8 30000 9 9500 channelOvercurrentTurnOffLimitSeconds 0 11 1 2 2 2 3 2 4 2 5 2 6 2 7 2...

Страница 179: ...7 1 8 1 9 1 channelTurnOnDelayOnStartup 0 3 1 3 2 4 3 5 4 6 5 7 6 8 7 9 8 10 9 11 channelTurnOffOnInputOverloadPriority 0 7 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 lineMinimumVoltage 1 45 2 90 lineMaximum...

Страница 180: ...6 65535 7 65535 8 65535 9 65535 lineAccumulatedSantiWattsMilliseconds 1 138642237555 2 138642237555 channelAccumulatedSantiWattsMilliseconds 0 0 1 126366924083 2 0 3 12255947235 4 0 5 0 6 1105525 7 0...

Страница 181: ...T api outlet channelNumber Parameter channelNumber Outlet number of interest The return is admS ON actS ON t1C ON t2C ON cbFS OFF fSC1 0 fSC2 0 oAFS OFF oTFS OFF loTFS OFF rS OFF ovTFS OFF iMa 0 iWa 0...

Страница 182: ...ed state Example curl X PUT http 10 210 1 52 8888 api channel 0 on curl X PUT http 10 210 1 52 8888 api channel 0 off REPLY rOLC OK ats channels 0 admS ON actS ON t1C ON t2C ON cbFS OFF fSC1 0 fSC2 0...

Страница 183: ...for inlets if mask 0 turn off recognition for all if mask 3 turn off recognition 0 and 1 outlets REPLY GET api status is used as a system response Example curl X PUT http 192 168 1 24 8888 api recogn...

Страница 184: ...192 168 1 24 8888 api output 1 restart 5 2 4 7 Outlet Reboot with a Delay Command PUT api channel output outlet channelNumber restart restartDelay Parameters channelNumber 0 9 restartDelay 1 65535 Exa...

Страница 185: ...t inputNumber activate Parameters inputNumber input number 1 2 REPLY GET api status is used as a system response Example curl X PUT http 192 168 1 24 8888 api input 1 activate 5 2 5 3 Current Limit Se...

Страница 186: ...astCommand OK time 2020 11 05 11 33 33 0300 5 2 6 2 Date and Time Setting Command PUT api rtc timeData Parameters timeData is a value consisting of year month day hour minute second Example curl X PUT...

Страница 187: ...Setting Command PUT api display user message Parameters message fgColor Return is true Example curl X PUT http 192 168 1 42 8888 api display user message d fgColor grey message hello 5 2 8 2 Default M...

Страница 188: ...formation About Allowed Colors Command GET api display allow colors REPLY red green blue yellow purple grey Example curl X GET http 192 168 1 42 8888 api display allow colors 5 2 8 6 What Variants Is...

Страница 189: ...rmTime null restartRequested false restartRequestedTime null lastCheckTime null lastAlarmMilliamps null lastRestartMilliamps null instantValues instantOutputsMilliamps sumInstantOutputsMilliamps null...

Страница 190: ...tatus MHS av MHS 5s rows 0 Y Alive 3560577 23 2060526 22 1 Y Alive 5074930 01 9017298 11 2 Y Alive 3384514 66 2721771 11 Total Hash Rate AV in MH s 12020021 9 Total Hash Rate 5s in MH s 13799595 44 6...

Страница 191: ...stAlarmTime null restartRequested false restartRequestedTime null lastCheckTime null instantValues alarmPacketPercentage null restartPacketPercentage null tcpPortAvailability alarm false lastAlarmTime...

Страница 192: ...fan6 2760 fan7 0 fan8 0 temp_num 3 temp1 0 temp2 0 temp3 0 temp4 0 temp5 0 temp6 0 temp7 0 temp8 0 temp9 0 temp10 0 temp11 0 temp12 0 temp13 0 temp14 0 temp15 0 temp16 0 temp2_1 0 temp2_2 0 temp2_3 0...

Страница 193: ...mp_pcb_14 temp_pcb_15 temp_pcb_16 temp_chip_1 temp_chip_2 temp_chip_3 temp_chip_4 temp_chip_5 temp_chip_6 15 15 temp_chip_7 temp_chip_8 15 15 temp_chip_9 temp_chip_10 temp_chip_11 temp_chip_12 temp_ch...

Страница 194: ...chain_rateideal16 0 temp_max 0 Device Hardware 0 0013 no_matching_work 20911 chain_acn1 0 chain_acn2 0 chain_acn3 0 chain_acn4 0 chain_acn5 0 chain_acn6 84 chain_acn7 0 chain_acn8 84 chain_acn9 0 chai...

Страница 195: ...X63 1 X64 1 X65 1 X66 1 X67 1 X68 1 X69 1 X70 1 X71 1 X72 1 X73 1 X74 1 X75 1 X76 1 X77 1 X78 1 X79 1 X80 1 X81 1 X82 1 chain_xtime8 X4 1 X5 1 X6 1 X7 1 X8 1 X9 1 X10 1 X11 1 X12 1 X13 1 X14 1 X15 1...

Страница 196: ...nd GET api automation device types REPLY 1 name Bitmain_D3 settings checkIntervalSeconds 6 interRestartIntervalSeconds 600 consumption alarmBottomLimitMilliamps 4500 restartBottomLimitMilliamps 4300 a...

Страница 197: ...60 restartSeconds 300 3 name Bitmain_S9 settings checkIntervalSeconds 6 interRestartIntervalSeconds 600 consumption alarmBottomLimitMilliamps 6600 restartBottomLimitMilliamps 6300 alarmSeconds 60 res...

Страница 198: ...4500 alarmSeconds 60 restartSeconds 300 hashRate hashrateMeasurementUnit MH s api port 3333 unavailabilityTimeoutSeconds 3 alarmBottomLimit 180 restartBottomLimit 170 alarmSeconds 60 restartSeconds 3...

Страница 199: ...conds 60 restartSeconds 300 8 name Bitmain_T15 settings checkIntervalSeconds 6 interRestartIntervalSeconds 600 consumption alarmBottomLimitMilliamps 6600 restartBottomLimitMilliamps 6300 alarmSeconds...

Страница 200: ...larmSeconds null restartSeconds null hashRate hashrateMeasurementUnit null api port null unavailabilityTimeoutSeconds null alarmBottomLimit null restartBottomLimit null alarmSeconds null restartSecond...

Страница 201: ...null restartSeconds null 13 name Small Switch settings checkIntervalSeconds 6 interRestartIntervalSeconds 600 consumption alarmBottomLimitMilliamps null restartBottomLimitMilliamps null alarmSeconds n...

Страница 202: ...l alarmSeconds null restartSeconds null hashRate hashrateMeasurementUnit null api port null unavailabilityTimeoutSeconds null alarmBottomLimit null restartBottomLimit null alarmSeconds null restartSec...

Страница 203: ...onds null restartSeconds null 18 name Large Server settings checkIntervalSeconds 6 interRestartIntervalSeconds 600 consumption alarmBottomLimitMilliamps null restartBottomLimitMilliamps null alarmSeco...

Страница 204: ...ottomLimitMilliamps null restartBottomLimitMilliamps null alarmSeconds null restartSeconds null hashRate hashrateMeasurementUnit null api port null unavailabilityTimeoutSeconds null alarmBottomLimit n...

Страница 205: ...rLimitMilliseconds null alarmPacketLossPercentage null restartPacketLossPercentage null alarmSeconds null restartSeconds null enabled false tcpPortAvailability ipAddress null port null connectTimeout...

Страница 206: ...168 1 10 8888 api automation devices 5 2 9 4 Automation Set Up Command POST api automation Parameters deviceType ID deviceType name name digitals letters symbols _ from 0 to 25 characters description...

Страница 207: ...ers a restart GH s from 1 to 5 digits hashRateAlarmSeconds stabilization delay in seconds for alarm s from 1 to 5 digits hashRateRestartSeconds stabilization delay in seconds for restart s from 1 to 5...

Страница 208: ...ds 300 hashRateApi Port 4028 hashRateApiUnavailabilityTimeoutSeconds 3 hashRateAlarmBottomLimit 16700 h ashRateAlarmSeconds 60 hashRateRestartBottomLimit 16500 hashRateRestartSeconds 300 i nterRestart...

Страница 209: ...alue reaching of which triggers an alarm GH s number 1 to 7 digits hashRateRestartBottomLimit the bottom threshold of the hashrate value reaching of which triggers a restart GH s from 1 to 5 digits ha...

Страница 210: ...true consumptionEnabled true deviceType 8201 checkIntervalSeconds 6 consumptionAlarmBottomLimitMilliamps 4500 consumptionAlarmSe conds 60 consumptionRestartBottomLimitMilliamps 4300 consumptionRestar...

Страница 211: ...les for a particular property or function service words are used on or off enable or disable Alarm Bottom Limit Milliamps value the lower current limit at which the alarm is triggered an integer from...

Страница 212: ...teger from 1 to 99999 TCP Port Value TCP port of a network device for checking the availability of a TCP service which must be checked an integer up to 65535 5 2 10 2 Adding Automation Test Settings C...

Страница 213: ...the Device Type Command PUT api automation name Automation Name value device type name Device Type Name value Example curl X PUT http 192 168 1 24 8888 api automation name Automation1 device type name...

Страница 214: ...bled value alarm bottom limit milliamps Alarm Bottom Limit Milliamps value restart bottom limit milliamps Restart Bottom Limit Milliamps value alarm seconds Timeout Alarm Seconds value restart seconds...

Страница 215: ...Test Command PUT api automation name Automation Name value consumption restart bottom limit milliamps Restart Bottom Limit Milliamps value Examples curl X PUT http 192 168 1 24 8888 api automation nam...

Страница 216: ...te enabled on alarm bottom limit default restart bottom limit default alarm seconds 20 restart seconds 40 api ip address 192 168 0 1 api port default api unavailability timeout seconds default 5 2 10...

Страница 217: ...m Seconds for a Hash Rate Test Command PUT api automation name Automation Name value hash rate alarm seconds Timeout Alarm Seconds value Examples curl X PUT http 192 168 1 24 8888 api automation name...

Страница 218: ...sh rate api unavailability timeout seconds 100 curl X PUT http 192 168 1 24 8888 api automation name Automation1 hash rate api unavailability timeout seconds default 5 2 10 29 Single Command for a Pin...

Страница 219: ...ds onnect Timeout Value Example curl X PUT http 192 168 1 24 8888 api automation name Automation1 ping connect timeout seconds 25 5 2 10 33 Setting Upper Limit Milliseconds for a Ping Command PUT api...

Страница 220: ...ing restart seconds 62 5 2 10 38 Configuring TCP Port Availability Test in One Command Command PUT api automation name Automation Name value tcp port availability enabled Enabled value ip address IP A...

Страница 221: ...42 Configuring Connect Timeout Seconds for a TCP Port Availability Test Command PUT api automation name Automation Name value tcp port availability connect timeout seconds onnect Timeout Value Exampl...

Страница 222: ...ltage detected frA frequencyAvailable The frequency at the input multiplied by 100 In order to get the actual frequency the value should be divided by 100 fre frequency Voltage vol voltage Accumulated...

Страница 223: ...s Over current limit in milliamperes for output without disabling input cOALM channelOvercurrentAlarmLimitMilliamps Pause to confirm current overflow before erecting the flag cOALS channelOvercurrentA...

Страница 224: ...ed on detection of current overload loTFS lineOvercurrentTurnOffFiredState The administrative status of the power on output cAS channelAdministrativeStatus Pause before powering on the device cTOD cha...

Страница 225: ...f RPCM and Connected Equipment 6 7 Command show all command allows to display different parameters for many objects at once 6 8 Command set command it is the main command to set the required values wi...

Страница 226: ...so on do not work with RPCM in poor communication conditions it is also recommended to always monitor the state of the system using the show all com mand sets carefully read the obsessed commands bef...

Страница 227: ...whoami show current user s username 6 2 2 Getting Help for a Specific Command After the command enter the service word help or question mark or simply press Enter This procedure can be repeated repea...

Страница 228: ...0 9 recognition state off to off on to on set output 0 9 overcurrent tune overcurrent limits alarm for alarming turn off for turning off set output 0 9 help show this help For example get help set out...

Страница 229: ...nctions will appear description help mode name off on overcurrent recognition 6 3 Exit commands for exit and quit These are two analogous commands that serve to properly conclude an SSH session Enteri...

Страница 230: ...dd email notificiation recipients add ntp add ntp configuration item server add ntp server add smtp add smtp configuration item server add smtp server add snmp add snmp configuration item community ad...

Страница 231: ...ult values for the parameters check interval seconds and inter restart inter val seconds check interval seconds the interval of checking the installed parameters in seconds inter restart interval seco...

Страница 232: ...n is delete automation device name device name to delete configured automation for Type help to get suggestions 6 4 2 Deleting with autocompletion Autocompletion of a parameter for example the device...

Страница 233: ...EVICE 1 delete automation device name DEVICE 1 The return is Automation Device ID 14 Name DEVICE 1 has been deleted Type help to get suggestions If we enter the same command again delete automation de...

Страница 234: ...ress for sending a carbon copy bcc address for sending a blind carbon copy The return is add mail The return is Please add email recipients example add mail recipient info example com cc duty example...

Страница 235: ...IP 192 168 1 251 delete ntp server 192 168 1 251 Server has been deleted 6 4 6 Commands add smtp server and delete smtp server These commands are used to set or delete the notification system setting...

Страница 236: ...cters Example add smtp server smtp gmail com port 587 helo gmail com username user gmail com pass word HelloWorld123 authType plain ssl enable add smtp server smtp yandex ru port 25 username user yand...

Страница 237: ...wever owing to the changes intro duced in it the performance of the protocol is significantly improved and security improvements are also made The third version of the protocol SNMPv3 already supports...

Страница 238: ...example accessList have the value 10 0 0 0 8 accessType has the value rw and en abled no add snmp community public accessList 10 0 0 0 8 accessType rw enabled no The return is Community public added T...

Страница 239: ...dd snmp user newrpcmuser Only after the second press of Tab does auto hint appear No user options specified for user newrpcmuser Example add snmp user newrpcmuser accessList 10 0 0 0 24 accessType ro...

Страница 240: ...p service Commands add snmp trap and delete snmp trap creates SNMP trap settings Show help add snmp trap v1 destination The return is Please set ip address of server which will catch traps and communi...

Страница 241: ...user Command add user Help ask add user The return is Username should start with letter numbers underscores or hyphens and be 2 to 32 charac ters long Command delete user Help displays delete user Pl...

Страница 242: ...ith the radius server are used to create and delete a RADIUS authen tication authorization server entry When creating the required parameters are filled in IP or FQDN of the RADIUS server secret acces...

Страница 243: ...gher is more priority Example add radius server 1 2 3 4 secret mySharedSecret enabled yes add radius server 1 2 3 4 secret mySuperSecretShared port 1812 Example It is creating a server with IP 192 168...

Страница 244: ...fter 0 9 mshd option to delay restart off delay 0 9 mshd option to set off delay restart help show this help An example of applying the command restart output to the output 0 restart output 0 Restarti...

Страница 245: ...indication For the user available is the option restart high level controller This construction is used to restart HLC for example during the update procedure In return the system issues a request to...

Страница 246: ...CM control system RPCM CLOUD button control displays show button control mode configuration displays configuration restoration statuses show display displays RPCM display settings everything displays...

Страница 247: ...mode show display show RPCM display settings show everything show everything important in one screen show group groupname show information about specific group show input 1 show information on partic...

Страница 248: ...s who are connected to the management system Example show active users The return is Record ID 1 Username rpcmadmin Group superuser IP Address 10 213 68 28 Interface WEB Authenticator local Expires 20...

Страница 249: ...nitor ing and control purposes reboot Note For more detailed information it is recommended to refer to the sections 4 11 Automation tools Required parameters name the name of the new device for automa...

Страница 250: ...ailability Timeout Sec 3 Ping Test Enabled OFF TCP Port Availability Test Enabled OFF Type help to get suggestions 6 6 7 Command show button control It displays permission for switch to Control mode o...

Страница 251: ...processes Command show configuration restore status The return is Idle Examples to upload configuration file scp RPCM_FirstBatchSeven_20181128_194640 config rpcmadmin 10 0 0 1 RPCM_FirstBatchSeven_201...

Страница 252: ...display user message The return is User Message RPCM FOR NETWORK Color green Type help to get suggestions Example 2 Get information what is default message Command show display default message The re...

Страница 253: ...A 0W Output 4 ON admin ON 0mA 0W Output 5 ON admin ON 0mA 0W Output 6 ON admin ON 0mA 0W Output 7 ON admin ON 0mA 0W Output 8 ON admin ON 0mA 0W Output 9 ON admin ON 0mA 0W Type help to get suggestion...

Страница 254: ...quired to specify the number of input 1 or 2 Example show input 1 The return is P N Input 1 Name name_num_1 Description On_The_Wall Voltage 48 321 Minimum Allowed Voltage 45 Maximum Allowed Voltage 58...

Страница 255: ...User x 192 168 7 79 authentication failed via ssh 2018 09 03 20 01 35 621 informational User x 192 168 7 79 authentication failed via ssh 2018 09 03 20 01 35 868 informational User x 192 168 7 79 aut...

Страница 256: ...sion id 20200904053832__10_213_117_156__local__3c754c44 2020 09 04 08 40 54 364 informational User rpcmadmin 10 210 1 148 authenticated success fully via WEB by local with session id 20200904054054__1...

Страница 257: ...101 There are Serial Names IP addresses and TTL in this list 6 6 17 Command show network It is used to display detailed information about the network access settings Example of use show network The r...

Страница 258: ...Overcurrent Alarm Limit Reached Times 0 Overcurrent Alarm Fired Facts 0 Overcurrent Turn Off Limit Milliamps 30000 Overcurrent Turn Off Limit Seconds 2 Overcurrent Turn Off Limit Reached Times 0 Overc...

Страница 259: ...mand show smtp It is used to display the settings of mail servers and recipient addresses Help for the keywords help and Is not available Example of use show smtp The return is SMTP Servers Server smt...

Страница 260: ...1 udp EngineID 8000B49B045250434D Context rpcm SNMP v1 v2c Configuration Community public Enabled YES AccessType ReadOnly accessList 10 0 0 0 8 Community management Enabled NO AccessType ReadWrite acc...

Страница 261: ...zones show time help show this help message 6 6 24 1 Getting information about the system time It is used simply as a show time output command with no parameters Example show time The return is Time c...

Страница 262: ...ica Montreal America Fort_Nelson America Adak America Lima America Edmonton America Boa_Vista America Los_Angeles America Winnipeg America Chihuahua America Bogota America Grenada America New_York Ame...

Страница 263: ...uala Africa Windhoek Africa Abidjan Africa Ndjamena Africa Lagos Africa Lubumbashi Africa Monrovia Africa Kigali Africa Freetown Africa Nairobi Africa Addis_Ababa Africa Djibouti Africa El_Aaiun Afric...

Страница 264: ...PDT GMT 0 WET CET Etc GMT 0 Etc GMT 8 Etc GMT 4 Etc GMT 1 Etc GMT 9 Etc GMT 11 Etc GMT Etc GMT 12 Etc GMT 10 Etc GMT 2 Etc GMT 6 Etc GMT 6 Etc Zulu Etc GMT 5 Etc GMT0 Etc GMT 9 Etc GMT 10 Etc GMT 5 Et...

Страница 265: ...imphu Asia Manila Asia Novosibirsk Asia Tashkent Asia Chita Asia Damascus Asia Almaty Asia Novokuznetsk Asia Dhaka Asia Kuching Turkey Greenwich Israel HST Factory 6 6 25 Command show update Displays...

Страница 266: ...s Status Update complete please manually restart RPCM Progress 100 For more details please refer to the section 4 7 Updating the RPCM Software 6 6 26 Command show user It is used to display detailed i...

Страница 267: ...er 2020 04 06 21 18 40 3600s 1303s ssh 10 213 97 208 superuser 2020 04 21 23 19 52 3600s 0s Type help to get suggestions In particular you can see the data Username User Disabled if NO user enabled Ac...

Страница 268: ...well as the serial name serial number uptime and system time Example show version Information about the RPCM module Serial Name AntiGeroy Serial Number RU2017101100000002MO01DN01 Model 1502 Hardware V...

Страница 269: ...nfigured automations show all counters show counters for device like circuit breaker firings alarm limit firings and overload turn off firings show all groups show information about all groups show al...

Страница 270: ...1 0 2 Antminer_S9 Bitmain_S9 1 3 Antminer_D3 Bitmain_D3 1 4 Antminer_L3_plus Bitmain_L3 1 5 nonexistent_claymore Claymore 1 Type help to get suggestions A similar list displays for any other parameter...

Страница 271: ...tput 7 0 0 0 0 0 Output 8 3 0 0 0 0 Output 9 2 0 0 0 0 6 7 3 Command show all groups Show an information about all security groups with permissions Note Object permissions in RPCM have to set UNIX sty...

Страница 272: ...kup configuration Restart High Level Controller etc Glb Global config Inp Inputs 1 2 Ou Outputs 0 9 Log System logs Aut Automation configuration Utl Utilities Type help to get suggestions 6 7 4 Comman...

Страница 273: ...0V 240V 49 99Hz 45 00Hz 65 00Hz 6 7 4 4 Command show all inputs meter readings It indicates the value of the meters Example of use show all inputs meter readings Information from the meters Instant In...

Страница 274: ...n ON 0mA 0W Output 5 ON admin ON 0mA 0W Output 6 ON admin ON 0mA 0W Output 7 ON admin ON 0mA 0W Output 8 ON admin ON 0mA 0W Output 9 ON admin ON 0mA 0W For the show all outputs a hint is available wit...

Страница 275: ...0 0 disabled Output 5 0 NO 10000 2 0 0 disabled Output 6 0 NO 10000 5 33 33 disabled Output 7 0 NO 10000 2 0 0 disabled Output 8 0 NO 10000 2 0 0 disabled Output 9 0 NO 9990 2 0 0 disabled Type help t...

Страница 276: ...65535 Output 3 230 OFF disabled disabled 65535 Output 4 230 OFF disabled disabled 65535 Output 5 230 OFF disabled disabled 65535 Output 6 230 OFF disabled disabled 65535 Output 7 230 OFF disabled disa...

Страница 277: ...order of switching off the voltage supply to the outlets with a general excess of the permissible current For RPCM 1502 the total current limit is 16A for RPCM 1532 32A for RPCM ME 1563 63A The highe...

Страница 278: ...ervers Show an information about RADIUS servers The notation of a list Prio server priority lower number is higher priority Server a RADIUS server address Port a port and the protocol Options addition...

Страница 279: ...tor Last Login Disabled nightuser administrators LOCAL RADIUS 2019 12 12 01 18 47 NO rpcmadmin superuser LOCAL 2020 04 08 21 21 52 NO nightuser2 rpcmadmingroup RADIUS 2020 04 08 18 35 59 0000 NO newus...

Страница 280: ...12 18 47 18 2019 04 12 18 48 06 rpcmadmin WEB 2019 04 16 15 07 21 2019 04 16 19 52 52 0000 rpcmadmin WEB 2019 04 16 15 39 01 2019 04 16 19 52 52 0000 rpcmadmin ssh 2019 04 16 17 44 44 2019 04 16 18 47...

Страница 281: ...allows you to set up a variety of settings for each of the inputs output for managing the outlet allows you to set up a variety of settings for each of the outlets radius server settings of server RAD...

Страница 282: ...make input active available on RPCM1502 RPCM1532 current limit set total input current limit description set input description frequency limit set input frequency limits max top value min bottom valu...

Страница 283: ...disables confirmation of critical operations disconnecting and resetting power leads The web interface corresponds to the setting in the menu Configuration Global options Get second confirmation from...

Страница 284: ...force failback turn off on and set failback delay Help ask set all inputs The return is set all inputs force failback delay Sets Force Failback Delay switching for Inputs in seconds on Enables Force F...

Страница 285: ...ack to OFF and ON Turn OFF command set all outputs off The return is Turning outputs 0 9 OFF oooooooooo Output 0 OFF admin OFF 0mA 0W Output 1 OFF admin OFF 0mA 0W Output 2 OFF admin OFF 0mA 0W Output...

Страница 286: ...key authentication service using enable disable pa rameters Help call set api The return is RPCM Commands help set api generate new key generate new access key for API set api key enable disable enabl...

Страница 287: ...p to get suggestions Re enable authentication service set api authentication enable The return is API Authentication successful enabled Type help to get suggestions 6 8 5 Command set button control Tu...

Страница 288: ...meter turns on the speaker sound of the RPCM module which helps to find the device in the rack The parameter off disables the speaker sound of the RPCM module The parameter alternate changes the speak...

Страница 289: ...sable permission or prohibit export telemetry information Help ask set cloud The return is set cloud exportTelemetry enable enables export telemetry information to RPCM CLOUD disable disables export t...

Страница 290: ...or a message specified by the user Help set display The return is set display user message custom message to be displayed set display default message parameter that will be Type help to get suggestio...

Страница 291: ...ss set display default message voltage Type help to get suggestions To set a custom message as the default set display default message userMessage The return is Default Message changed from voltage to...

Страница 292: ...sion of access to system tools IMPORTANT Prohibition or permission as well as a change in account privileges occurs imme diately without a request for confirmation from the user Please consider this i...

Страница 293: ...escription a comment max 256 allowed digits english alphabetic symbols symbols minus underlining and space frequency setting frequency limits current setting max current limit in Amps when the limit i...

Страница 294: ...ggestions Example 1 Setting input 1 as active for RPCM with ATS only Command set input 1 active The return is Active Input is set to 1 Type help to get suggestions Example 2 Setting input 1 as priorit...

Страница 295: ...Main Line Voltage 48 321 Minimum Allowed Voltage 45 Maximum Allowed Voltage 58 Maximum Allowed Current Amps 200 Instant Milliamps 0 Instant Watts 0 Accumulated KWh 0 382778 Example 5 Turning on recog...

Страница 296: ...cy limit min 48 max 61 The return is Minimum frequency value is set to 48 00Hz for Input 1 Maximum frequency value is set to 61 00Hz for input 1 Type help to get suggestions 6 8 10 2 Command set input...

Страница 297: ...voltage limit min 45 max 51 The return is Minimum voltage value is set to 45 for Input 1 Maximum voltage value is set to 51 for Input 1 Type help to get suggestions Type help to get suggestions 6 8 1...

Страница 298: ...e help to get suggestions Example Set RADIUS server priority IP 192 168 1 1 to 12 The command is set radius server 192 168 1 1 secret password key priority 12 The return is Radius server 192 168 1 1 u...

Страница 299: ...nd set snmp community It controls the configuration of access via SNMP version 1 and 2c Options available are the following accessList allowed subnet or a separate IP address accessType access type ro...

Страница 300: ...this property can be changed later values are yes or no privPass keyword password for encryption privProt type of encryption secLevel type of authentication Attention There is no standard hint output...

Страница 301: ...Set the system time Help displays set time value The return is Setting time to Please specify the date and time or just the time in the following format YYYY MM DD HH MM SS Example 2017 06 05 14 32 1...

Страница 302: ...set user 6 8 14 1 General information It is used to enabling or disabling user Available parameters accessLevel setting privilege level disabled enabled password changing user password IMPORTANT Prohi...

Страница 303: ...set user newuser accessLevel superuser The return is Access Level has been successfully changed Type help to get suggestions 6 8 14 3 Disable or enable some user How to disable user The command is set...

Страница 304: ...ully confirmation Password has been successfully changed Type help to get suggestions Password has to include english letters numbers and symbols underline and hyphen If new password has non available...

Страница 305: ...off turn off configuration disabled disable it limit volts 0 65534 set limit in volts set output 0 9 recognition set output 0 9 recognition state off to off on to on set output 0 9 recover turn on set...

Страница 306: ...atively includes the specified outlet from 0 to 9 Example of use set output 9 on The return is Output 9 ON admin ON 0mA 0W 6 9 5 Command set output overcurrent it allows you to control power current c...

Страница 307: ...in seconds set output 0 9 overcurrent alarm limit help show this help Example 1 Setting alarm outlet limit to 9A to outlet 9 Command set output 9 overcurrent alarm limit amps 9 00 The return is New ov...

Страница 308: ...turn off limit for output 9 is 9 5 amps was 10 0 amps Example 2 Setting the delay for turn off to 5 seconds for the outlet 9 set output 9 overcurrent turn off limit seconds 5 The return is New overcu...

Страница 309: ...Type help to get suggestions Example 2 Disabling an overvoltage turn OFF limit Command set output 0 overvoltage turn off limit disabled The return is Disable overvoltage turn off limit for output 0 wa...

Страница 310: ...e the device is connected one or more in the format 0 9 or 0 9 0 9 check interval seconds check interval in seconds inter restart interval seconds the protection interval between reboots in seconds te...

Страница 311: ...2 The return is Description changed from to New_Description_for_DEVICE 2 6 10 2 Command set automation test Used to configure test methods select and configure parameters for verification Contains fol...

Страница 312: ...yes no enables Consumption test alarm bottom limit milliamps alarm bottom limit milliamps of automatio n device restart bottom limit milliamps restart bottom limit milliamps of automat ion device alar...

Страница 313: ...nsumption Restart Seconds set to 300 Type help to get suggestions Example 2 Turn off current consumption testing for this device set automation device name DEVICE 2 test consumption enabled no The ret...

Страница 314: ...reaching the restart bottom limit default set default values for all parameters Example set automation device name testName test hashrate enabled yes api ip address 127 0 0 1 default set automation d...

Страница 315: ...automation device test ping This design is designed to configure the monitoring method using ICMP packets similar to the ping command Available options enabled answer yes or no to enable enable this c...

Страница 316: ...tage 80 alarm seconds 10 restart seconds 60 set automation device name testName test ping connect timeout seconds 4 set automation device name testName test ping enabled no Type help to get suggestion...

Страница 317: ...ce connect timeout seconds connect timeout in seconds alarm seconds time in seconds to trigger the alarm after reaching the connect timeout seconds restart seconds time in seconds to trigger the resta...

Страница 318: ...t to 80 TCP Port Availability Connect Timeout set to 3 TCP Port Availability Alarm Seconds set to 10 TCP Port Availability Restart Seconds set to 60 Type help to get suggestions Example 2 Disable test...

Страница 319: ...be uploaded Type help to get suggestions 6 11 2 Command start update It is used to start the system update process after downloading the update file Help ask start update The return is We are not read...

Страница 320: ...yes start configuration restore with reset to default yes skip invalid param s yes start configuration restore skip invalid params yes Type help to get suggestions Parameters with reset to default ye...

Страница 321: ...eference of RPCM CLI The return is Process of restoring the configuration Progress 6 Type help to get suggestions Next step you need to restart High Level Controller HLC Command restart high level con...

Страница 322: ...on about the command RPCM Commands description ping hostname or ip ICMP ping to ip address or hostname Use ping 192 168 1 254 The return is Ping 192 168 1 254 192 168 1 254 64 bytes from 192 168 1 254...

Страница 323: ...date procedure remove all uploaded data and start recovery procedure cancel configuration restore abort configuration restore procedure it will remove uploaded configuration Type help to get suggestio...

Страница 324: ...ing contains information about the main ways to eliminate minor problems as well as about contacting support services Appendix 2 Specifications describes the technical characteristics functions of the...

Страница 325: ...failure Name of the characteristic Recommended actions The device does not turn on the indicators do not light up Check the following parameters the enclosure is not dam aged fluid has not entered th...

Страница 326: ...the IP address instead Verify that the network is function ing between the computer running the browser and the RPCM module for example using the network command ping Check that TCP port 22 is allowe...

Страница 327: ...d Check the presence of a short circuit or overload correct the problem and put the outlet into operational mode The connected device does not turn on the output indicator lights in blue Check that th...

Страница 328: ...protection adjustable 1 30 A default 30A short cir cuit protection tripping cur rent 87 5A Overload protection adjustable 0 1 30 A default 30A short circuit protection tripping cur rent 87 5A Electric...

Страница 329: ...reboot output outlet when TCP port is unavailable channel re set output outlet with de creasing current Channel reboot output out let while decreasing the hashrate of miners channel re set output out...

Страница 330: ...nnected grounding which should ensure the prevention of failure and equipment failures as well as increase electrical safety in the operation of the equip ment thanks to automatic monitoring and indic...

Страница 331: ...the use of low voltage equipment including those caused by physical chemical or biological fac tors the necessary level of insulation protection the necessary level of mechanical and wear resistance t...

Страница 332: ...nterprise operating the product It is allowed to dispose of utilizations materials on a contractual basis with an organizations that has a license for ecological utilizations After the conclusion of t...

Страница 333: ...trol and monitoring Output see Outlet RTC Real Time Clock ATS Automatic Transfer Switch a functionality that detects absence of voltage on main power input or degradation of power input quality and sw...

Страница 334: ...ier MAC address is assigned to each physical interface in Ethernet family networks SSH Secure Shell application level protocol of the TCP IP stack The main application is emulation of the CLI interfac...

Страница 335: ...area on the Top Control Bar and serves for relaying the in dicator on the front panel of the device Reflection Block see Virtual Front Panel Unlock Control Button intended for switching the Main Windo...

Страница 336: ...of the integrity of data including damage removal or unforeseen modification failure violation or modification of the operation of soft ware or hardware the operation of lines or communication channel...

Страница 337: ...part of this documentation may be reproduced or transmitted in any form or by any means electronic mechanical photocopying or recording on magnetic or other media Copyright to the device for flexible...

Отзывы: