CHAPTER 3 MAINTENANCE
6. Setting the Stored Stroke Limit
III
– 35
6.5 Precautions related to stroke limit
(1) When the maximum value and minimum value of the stored stroke limit's prohibited range are set
to the same data, note that the following will occur:
(a) When the maximum value and minimum value are set to the same data, if the outside is the
prohibited range, the entire range will be prohibited. If the inside is the prohibited range, the
entire range will be the moveable range.
(2) Stored stroke limit
I
C is validated by changing the axis specification parameter "130027 IB_off".
(3) Make sure that the lower limit value of the stored stroke limit
I
C setting value is smaller than the
upper limit value.
(4) Movement in the prohibited range is limited to that in the direction that approaches both
I
and
I
C.
:
Moveable
direction
Moveable range by
I
C
Moveable range by
I