CHAPTER 1 SCREEN OPERATIONS
2. Monitor (Operation) Screens
I
– 105
2.10.3 Control parameter 2 details
The control parameters for each system are displayed and set on this screen.
For parameters indicated with a "
∗
" in the table, turn the NC power OFF after setting. The setting is
validated after the power is turned ON again.
# Item
Setting
Details
320001 G00 dry run
ON
The external manual feedrate is enabled in respect to rapid
traverse (G0, G27, G28, G29, G30, G60).
OFF
The "rapid traverse rate × rapid traverse override value" set in
the machine parameters is applied.
320002 Macro single
ON
The macro block is handled as one block. The single block
operation can be stopped at each macro block.
OFF
The macro block is not handled as one block. The program is
processed at a high speed.
320003 Middle
point
ignore
ON
During G28, G30 reference point return command, the middle
point designated in the program is ignored, and the axis returns
directly to the reference point.
OFF
During G28, G30, the program designation is followed, and the
axis returns to the reference point via the middle point.
320004 Machine
lock
rapid
ON
When carrying out automatic operation in the machine lock
state, the feedrate becomes the machine lock speed. The
machine lock speed is set with the machine parameter's Base
system param "120072 M_lock rapid feed".
OFF
During machine lock, the feedrate is the commanded speed,
and is the same process time as normal automatic operation.
320005 G04 time fixed
ON
The G04 command is a time designation in both the
synchronous feed mode (G95) and asynchronous feed mode
(G94).
OFF
The G04 command is a time designation in the asynchronous
feed mode (G94), and a rotation designation in the
synchronous feed mode (G95).
320006
ON
During the radius compensation interference check, the path is
changed so that the workpiece is not cut into by the tool radius.
Rad compen
intrf byp
(Note)
OFF
During the radius compensation interference check, if the block
is determined to cause cutting into the workpiece by the tool
radius, an alarm is generated before execution, and the
operation stops.
320007 Decimal
point
type 2
ON
1 of a position command data without a decimal point
command is controlled as 1mm (1 inch).
OFF
1 of a position command data without a decimal point
command is controlled as the min. input command unit
(0.01mm, 0.001mm or 0.0001mm) designated in the
specifications.
(Note)
If the control parameter "#320033 Tcomp interf chk OFF" is set to "OFF", the "#320006 Rad
compen intrf byp" setting is invalid. Even if the workpiece is cut into, an alarm is not
generated. Machining proceeds without changing the path.
Downloaded from
Содержание MELDAS 600M Series
Страница 1: ...CNC 600M Series INSTRUCTION MANUAL BNP B2237J ENG Downloaded from ManualsNet com search engine ...
Страница 15: ...CHAPTER 1 SCREEN OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 333: ...CHAPTER 2 MACHINE OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 386: ...CHAPTER 3 MAINTENANCE Downloaded from ManualsNet com search engine ...
Страница 442: ...CHAPTER 4 APPENDICES Downloaded from ManualsNet com search engine ...