6. Setting the Stored Stroke Limit
III
– 32
(1) Stored stroke limit
II
(When prohibited range is outside)
Used with the stored stroke limit
I
function, the confined range designated by the two functions
becomes the moveable range.
Point 2
P
roh
ib
ited r
an
ge
Range prohibited
with stored
stroke limit
II
Machine coordinate
system
Machine moveable
range
-
setting value
+ setting value
Point 4
P
roh
ib
ited r
an
ge
Point 1
Point 3
(2) Stored stroke limit
II
B (When prohibited range is inside)
A range besides the stored stroke limit
I
becomes the movement prohibited range.
Point 2
Point 4
Point 1
Point 3
Range prohibited
with stored
stroke limit
II
B
Machine coordinate
system
Machine movement
valid range
-
setting value
+ setting value
P
roh
ib
ited
ra
ng
e
P
roh
ib
ited
ra
ng
e
(3) Setting with program commands
With the stored stroke limit
II
(
II
B) function, the prohibited range (parameters) can be changed
and this function can be turned ON and OFF with the program commands. Refer to the section on
the program parameters inputs in the Programming Manual, and the Parameter Manual for details.
The following values are set with
the coordinate values in the
machine coordinate system:
Point 3: 340008 soft limit (–)
Point 4: 340009 soft limit (+)
The area determined by points 1
and 2 is the prohibited range set
with stored stroke limit
I
.
Downloaded from
Содержание MELDAS 600M Series
Страница 1: ...CNC 600M Series INSTRUCTION MANUAL BNP B2237J ENG Downloaded from ManualsNet com search engine ...
Страница 15: ...CHAPTER 1 SCREEN OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 333: ...CHAPTER 2 MACHINE OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 386: ...CHAPTER 3 MAINTENANCE Downloaded from ManualsNet com search engine ...
Страница 442: ...CHAPTER 4 APPENDICES Downloaded from ManualsNet com search engine ...