CHAPTER 4 APPENDICES
Appendix 4. Warning Messages
IV
– 58
4.5 Operation warnings (OPW
)
No. Message
Details
Remedy
OPW0101 Auto
operation
pause signal ON
The automatic operation
stopped because the automatic
operation stop signal turned ON.
•
The operation can be restarted by
canceling the automatic operation
stop signal.
OPW0102 Single block stop
signal ON
The block stopped because the
single block stop signal turned
ON.
•
Restarting will cause one block to
be executed and then the block
will stop. Canceling the single
block stop signal and starting will
cause continuous operation.
OPW0103 Verify stop
The operation is in a compare
stop state.
•
Restarting will cause the
continuous operation to restart.
OPW0104 External
interlock axis
exists
The external interlock function
has been validated and one of
the axes has entered the
interlock state.
•
Cancel the interlock signal.
OPW0105 Internal
interlock
axis exists
The servo OFF function is valid.
Or, an axis in an axis removal
state was commanded.
•
Cancel the servo OFF signal.
•
Cancel the command.
OPW0106 Operation
mode
change
The automatic operation mode
changed to another automatic
operation mode during
operation.
•
Return to the original automatic
operation mode, and restart.
OPW0107 No
operation
mode
Starting was attempted without
selecting the operation mode.
Or, canceling of the operation
mode was attempted during
operation.
•
Restart after selecting the
operation mode.
OPW0108 Operation
mode
duplicated
Starting was attempted with
duplicated operation modes, or
another duplicating operation
mode was selected during
operation.
•
Restart after selecting the
operation mode.
OPW0109 Cutting
override
zero
The cutting feed override switch
on the machine operation panel
is set to "0".
•
Set the switch to a value other
than "0" to cancel the error.
•
If the switch is set to a value other
than "0", check for a short circuit
in the signal wire.
•
Check the sequence program.
OPW0110 Rapid
feed
override zero
The "RAPID TRAVERSE
OVERRIDE" switch on the
machine operation panel is set
to "0".
•
Cancel the error by setting the
"RAPID TRAVERSE OVERRIDE"
switch to a value other than "0".
•
If the "RAPID TRAVERSE
OVERRIDE" switch is set to a
value other than "0", check for
short-circuits in the signal wire.
•
Check the sequence program.
Downloaded from
Содержание MELDAS 600M Series
Страница 1: ...CNC 600M Series INSTRUCTION MANUAL BNP B2237J ENG Downloaded from ManualsNet com search engine ...
Страница 15: ...CHAPTER 1 SCREEN OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 333: ...CHAPTER 2 MACHINE OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 386: ...CHAPTER 3 MAINTENANCE Downloaded from ManualsNet com search engine ...
Страница 442: ...CHAPTER 4 APPENDICES Downloaded from ManualsNet com search engine ...