CHAPTER 3 MAINTENANCE
4. Absolute Position Detection
III
– 22
(2) Resetting the absolute position basic point
After zero point initialization, the absolute position basic point can be reset by setting "2" for "1 Ref
position set" on the Zero point set screen. With this method, the parameters do not need to be
changed, and the power does not need to be turned OFF.
Operation procedure
"Status" display on Zero point set
screen
1. Select the Zero point set screen.
2. Push the Abs posn set menu key.
3. Designate the axis for which the
absolute position basic
point
is to be reset, and set "2" for the "1 Ref position set" of
that axis.
(Note 1)
4. Following the previously explained zero point initialization
procedures, carry out initialization again.
5. After the zero point has been initialized, turn the power ON
again.
6. After the axes have been returned to the zero point, output
the parameters.
"0" will appear at "Status" for the axis for
which the zero point has not been
initialized.
(Note 1)
When "2" is set for "1 Ref position set", the initialization will be incomplete, and an error will
occur. Always reset the absolute position basic point.
Downloaded from
Содержание MELDAS 600M Series
Страница 1: ...CNC 600M Series INSTRUCTION MANUAL BNP B2237J ENG Downloaded from ManualsNet com search engine ...
Страница 15: ...CHAPTER 1 SCREEN OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 333: ...CHAPTER 2 MACHINE OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 386: ...CHAPTER 3 MAINTENANCE Downloaded from ManualsNet com search engine ...
Страница 442: ...CHAPTER 4 APPENDICES Downloaded from ManualsNet com search engine ...