CHAPTER 1 SCREEN OPERATIONS
3. Setup Screens
I
– 174
Number
Name
Details
Setting range (units)
38 0007
Char length This sets the data bit length.
Refer to the item "38005 Parity valid" for details.
Set this to match the I/O device specifications.
0 : 5 (bit)
1 : 6
2 : 7
3 : 8
38 0008
Handshake
method
This is the RS-232C transmission control method.
Set this to match the control method of the connected
I/O device.
1 : RTS/CTS method
2 : No handshake
3 : DC code method
38 0009
Timeout
time
This sets the timeout time for detecting an interruption
in the data transmission during data input/output.
An error occurs if the one block read or 250
characters output time exceeds the designated time,
due to an I/O device fault or an exchange during
transmission.
Depending on the baud rate, the timeout time setting
must be changed.
The setting "0" is equivalent to approx. 90 minutes.
0 to 999 (1/10s)
38 0010
Data code
This sets the code to be used.
0 : ASCII code
1 : ISO code
38 0011
Check sum
This sets the validity of the computer link A check sum
function.
0 : Check sum invalid
1 : Check sum valid
38 0012
DC1 after
NAK or SYN
This sets the presence of a DC1 code output after the
NAK code or SYN code is output.
This is valid only when "3" is selected for "380008
Handshake method".
0 : Do not output DC1
code
1 : Output DC1 code
38 0013
Buffer
correction
This selects whether to validate the buffer correction
during operation
0 : Buffer correction
invalid
1 : Buffer correction valid
38 0014
Reset
validity
This sets whether to validate the reset during
computer link. Normally, this is set to "0".
0 : Computer link reset
valid
1 : Computer link reset
invalid
38 0015
CR output
This selects whether to output the CR code just
before the LF code.
0 : Do not output CR
code
1 : Output CR code
38 0016
DC code
parity
This is valid only when 3: DC code method is selected
for "380008 Handshake method".
The even parity in respect to the control code is
added. Set this to match the I/O device specifications.
0 : DC code with no
parity
1 : DC code with parity
38 0017
Parity V
This is set when the parity V in one block is to be
checked during data input.
0 : Invalid
1 : Valid
38 0018
Start code
This sets the code instructing the start of the first
transmission in the file data transmission.
This is intended for specific users, and is normally set
to "0".
This is valid only when 3: DC code method is selected
for "380008 Handshake method".
0 : DC1
1 : BEL
38 0019
NAK output
This selects whether to send an NAK code to the host
if a communication error occurs in computer link B.
0 : Do not output NAK
code
1 : Output NAK code
Downloaded from
Содержание MELDAS 600M Series
Страница 1: ...CNC 600M Series INSTRUCTION MANUAL BNP B2237J ENG Downloaded from ManualsNet com search engine ...
Страница 15: ...CHAPTER 1 SCREEN OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 333: ...CHAPTER 2 MACHINE OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 386: ...CHAPTER 3 MAINTENANCE Downloaded from ManualsNet com search engine ...
Страница 442: ...CHAPTER 4 APPENDICES Downloaded from ManualsNet com search engine ...