CHAPTER 1 SCREEN OPERATIONS
3. Setup Screens
I
– 175
Number
Name
Details
Setting range (units)
38 0020
SYN output
This selects whether to send a SYN code to the host if
an NC reset or emergency stop occurs in computer
link B.
0 : Do not output SYN
code
1 : Output SYN code
38 0021
DC3 output
This selects whether to send a DC3 code to the host
when the communication is completed in computer
link B.
This is valid only when 3: DC code method is selected
for "380008 Handshake method".
0 : Do not output DC3
code
1 : Output DC3 code
38 0022
Wait time
When a command is received from the host in
computer link A, a reply command is returned after
the time set in the wait time has passed. Also, during
the machining program download, the file
transmission start code (DC1 or BEL) is sent after
waiting the set time.
0 to 255 (1/10s)
38 0023
Buffer size
The DC3 code is output when the several bytes of
data set in buffer size is received.
Normally, "4096" is set.
248 to 4096 (byte)
38 0024
Operation
start size
Operation starts when enough data is received in the
reception buffer.
Set a value less than "380026 DC 3 output size".
Normally, "248" is set.
248 to "380026 DC3
output size" setting value
(byte)
38 0025
DC1 output
size
The DC1 code is output when the number of data
items in the reception buffer drops to below the
number of bytes set in the DC1 output size.
Normally, the same value as "380026 DC3 output
size" is set.
248 to "380026 DC3
output size" setting value
(byte)
38 0026
DC3 output
size
The DC3 code is output when the number of data
items in the reception buffer drops to below the
number of bytes set in the DC3 output size.
Normally, this is set as "380023 Buffer size" –16.
Normally, set "4000".
248 to "380023 Buffer
size" setting value –16
(byte)
38 0027
Poling time This sets the time to wait after the control code in
respect to the data sent from the host is received by
the host, or after the control code in respect to the
data sent from the NC is received.
The next data or control code is transmitted after the
set time has passed.
0 to 999 (1/10s)
38 0028
Retry
counter
The number of times to retransmit the data when the
data sent to the host or the data sent from the host is
found illegal after inspections such as check sum.
0 to 99 (times)
Downloaded from
Содержание MELDAS 600M Series
Страница 1: ...CNC 600M Series INSTRUCTION MANUAL BNP B2237J ENG Downloaded from ManualsNet com search engine ...
Страница 15: ...CHAPTER 1 SCREEN OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 333: ...CHAPTER 2 MACHINE OPERATIONS Downloaded from ManualsNet com search engine ...
Страница 386: ...CHAPTER 3 MAINTENANCE Downloaded from ManualsNet com search engine ...
Страница 442: ...CHAPTER 4 APPENDICES Downloaded from ManualsNet com search engine ...